摘要

The Atmospheric Chemistry Experiment (ACE) mission was launched in August 2003 to sound the atmosphere by solar occultation. Carbon monoxide (CO), a good tracer of pollution plumes and atmospheric dynamics, is one of the key species provided by the primary instrument, the ACE-Fourier Transform Spectrometer (ACE-FTS). This instrument performs measurements in both the CO 1-0 and 2-0 ro-vibrational bands, from which vertically resolved CO concentration profiles are retrieved, from the mid-troposphere to the thermosphere. This paper presents an updated description of the ACE-FTS version 2.2 CO data product, along with a comprehensive validation of these profiles using available observations (February 2004 to December 2006). We have compared the CO partial columns with ground-based measurements using Fourier transform infrared spectroscopy and millimeter wave radiometry, and the volume mixing ratio profiles with airborne (both high-altitude balloon flight and airplane) observations. CO satellite observations provided by nadir-looking instruments (MOPITT and TES) as well as limb-viewing remote sensors (MIPAS, SMR and MLS) were also compared with the ACE-FTS CO products. We show that the ACE-FTS measurements provide CO profiles with small retrieval errors (better than 5% from the upper troposphere to 40 km, and better than 10% above). These observations agree well with the correlative measurements, considering the rather loose coincidence criteria in some cases. Based on the validation exercise we assess the following uncertainties to the ACE-FTS measurement data: better than 15% in the upper troposphere (8–12 km), than 30% in the lower stratosphere (12–30 km), and than 25% from 30 to 100 km.
机译:大气化学实验(ACE)任务于2003年8月启动,目的是通过太阳掩星来听起来大气。一氧化碳(CO)是污染羽流和大气动力学的良好示踪剂,是主要仪器ACE-傅立叶变换光谱仪(ACE-FTS)提供的关键物种之一。该仪器在CO 1-0和2-0旋转振动带中执行测量,从对流层中部到热层从中获取垂直解析的CO浓度曲线。本文介绍了ACE-FTS 2.2版CO数据产品的更新说明,并使用可用的观测值(2004年2月至2006年12月)全面验证了这些剖面。我们将CO部分色谱柱与使用傅立叶变换红外光谱法和毫米波辐射测定法进行的基于地面的测量进行了比较,并将体积混合比曲线与机载(高空气球飞行和飞机)观测进行了比较。天底观测仪器(MOPITT和TES)以及四肢观察遥感器(MIPAS,SMR和MLS)提供的CO卫星观测值也与ACE-FTS CO产品进行了比较。我们表明,ACE-FTS测量结果为CO剖面提供了较小的取回误差(从对流层上方至40 km处,优于5%,而高于对流层则高于10%)。考虑到在某些情况下相当宽松的重合标准,这些观察结果与相关度量非常吻合。在验证工作的基础上,我们评估了ACE-FTS测量数据的以下不确定性:对流层上方(8–12 km)优于15%,平流层较低(12–30 km)高于30%,对流层低于25从30到100公里的百分比。

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号