首页> 外文OA文献 >Scintimammography with technetium-99m methoxyisobutylisonitrile: results of a prospective European multicentre trial.
【2h】

Scintimammography with technetium-99m methoxyisobutylisonitrile: results of a prospective European multicentre trial.

机译:用int 99m甲氧基异丁基异腈进行闪烁X线摄影:一项前瞻性欧洲多中心试验的结果。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of the trial was to determine the diagnostic accuracy of scintimmammography with technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) in the detection of primary breast cancer and to verify its clinical usefulness. A total of 246 patients with a suspicious breast mass or positive mammogram were included in this prospective European multicentre trial. At 5 min and 60 min (optional) p.i. two lateral prone images were acquired for 10 min each; 30 min p.i. one anterior image was acquired for 10 min. There were 253 lesions (195 palpable and 58 non-palpable), in respect of which histology revealed 165 cancers and 88 benign lesions. Institutional and blinded read results were correlated to core laboratory histopathology results obtained during excisional biopsy. Diagnostic accuracy for the detection of breast cancer was calculated per lesion. The overall sensitivity and specificity of blinded read scintimammography were 71% and 69%, respectively. For palpable lesions, the sensitivity of blinded read and institutional read scintimammography was 83% and 91%, respectively. Sensitivity was not dependent on the density of the breast tissue. Invasive ductal and invasive lobular cancers showed similar sensitivity. The sensitivity and specificity of mammography were 91% and 42%, respectively, and did not depend on the tumour size. In 60% of false-negative mammograms, 99mTc-MIBI was able to diagnose malignancy (true-positive). High-quality imaging with 99mTc-MIBI has a high diagnostic accuracy for the detection of primary breast cancer. Used as a complementary method, scintimammography with 99mTc-MIBI can help to diagnose breast cancer at an earlier stage in patients with dense breasts.
机译:该试验的目的是确定使用99m甲氧基异丁基异腈(99mTc-MIBI)进行闪烁X线断层摄影术对原发性乳腺癌的诊断准确性,并验证其临床实用性。这项前瞻性的欧洲多中心试验共纳入246名可疑乳腺肿块或乳房X线检查阳性的患者。在5分钟和60分钟(可选)时分别采集两个横向俯卧图像,每次10分钟;每天30分钟采集一张前图像10分钟。有253个病变(可触及195个病变,不可触及58个病变),就组织学而言,有165个癌症和88个良性病变。机构和盲读结果与切除活检过程中获得的核心实验室组织病理学结果相关。计算每个病变的乳腺癌检测诊断准确性。盲法闪烁X线摄影的总体敏感性和特异性分别为71%和69%。对于可触及的病变,盲法和机构性闪烁体层摄影术的敏感性分别为83%和91%。敏感性不取决于乳房组织的密度。浸润性导管癌和浸润性小叶癌显示相似的敏感性。乳腺X线摄影的敏感性和特异性分别为91%和42%,并且与肿瘤的大小无关。在60%的假阴性乳房X光照片中,99mTc-MIBI能够诊断出恶性肿瘤(真阳性)。使用99mTc-MIBI进行的高质量成像对原发性乳腺癌的检测具有很高的诊断准确性。带有99mTc-MIBI的闪烁体X线照相法作为一种补充方法,可以帮助在乳腺密集的患者中早期诊断出乳腺癌。

著录项

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号