Objective : The thesis has as main goal the improvement of electrical safety in surgical procedures. It can be find risks of health hazards of the patients from the use of electromedical equipment (EME) that operates with electricity and are susceptible to failure. The consequence of these electrical failures taken into account in this thesis is a differential current (leakage) improper passing through a patient’s body, thus creating a microshock. Materials and Methods : A literature review was performed, concerning the electrical safety norms related with EMEs, facilities in critical hospital environments such as surgical centers and physiological effects of electrical current on the human body. A study about mathematical/statistical methods that can be used to calculate similarity between electrical current waveforms was also built. Therefore, a reference platform capable of capturing EMEs differential current during surgical procedures was developed. Accordingly, a methodology of differential current analysis is proposed, generating a scale of dangerousness relating to electrical current value, frequency spectrum and the similarity between simultaneous waveforms. Results : The reference platform was validated in the laboratory using TN-S and IT medical earthing systems. For validation, in both grounding systems were artificially produced leakage currents and microshocks, which were analyzed in the scales dangerousness proposed. Furthermore, differential current events were captured with the reference platform embedded in gas and socket panel of an operating room, in order to provide an evaluation in real environment of use. Discussion of results : laboratory tests have proven that the reference platform is able to capture the differential current events with the necessary precision to a broad analysis. The proposed dangerousness scales proved to be adequate for the analysis of the events captured in six months of use at the surgical center. In this period, at least 49 situations with danger alert were detected. With the similarity scale between electric current waveforms, progress was made in the detection of microshock. Conclusion : It can be stated that this thesis contributed to the improvement of electrical safety during surgical procedures. The reference platform, using the dangerousness scale proposed, can distinguish between a meaningless event and an event with a real risk. Maybe in the future, the knowledge produced in this thesis can incorporate electrical safety norms in surgical procedures.
机译:目的:本文的主要目标是提高手术过程中的电气安全性。通过使用带电操作且容易发生故障的电子医疗设备(EME),可以发现对患者健康造成危害的风险。本文中考虑的这些电气故障的结果是不适当地通过患者身体的差动电流(泄漏),从而产生了微震。材料和方法:进行了文献综述,涉及与EME有关的电气安全规范,关键医院环境中的设施(如手术中心)和电流对人体的生理影响。还建立了可用于计算电流波形之间相似度的数学/统计方法的研究。因此,开发了一种能够在外科手术过程中捕获EME差动电流的参考平台。因此,提出了一种差分电流分析的方法,该方法产生与电流值,频谱以及同时波形之间的相似性有关的危险等级。结果:参考平台已在实验室中使用TN-S和IT医疗接地系统进行了验证。为了进行验证,在两个接地系统中均人为地产生了泄漏电流和微震,并在建议的危险等级中对其进行了分析。此外,利用嵌入手术室气体和插座面板中的参考平台捕获了差动电流事件,以便在实际使用环境中提供评估。结果讨论:实验室测试已证明参考平台能够以必要的精度捕获差动电流事件,以进行广泛的分析。事实证明,拟议的危险等级足以分析在手术中心使用六个月后捕获的事件。在此期间,至少检测到49种带有危险警报的情况。利用电流波形之间的相似度,微震的检测取得了进展。结论:可以说,该论文有助于提高手术过程中的电气安全性。参考平台使用建议的危险等级,可以区分无意义的事件和具有实际风险的事件。也许在将来,本文所产生的知识可以将电气安全规范纳入手术程序中。

著录项

  • 作者

    Rebonatto Marcelo Trindade;

  • 作者单位
  • 年度 2015
  • 总页数
  • 原文格式 PDF
  • 正文语种 Português
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号