首页> 外文OA文献 >Stable long-term operation of superconducting current-feeder system for the LHD
【2h】

Stable long-term operation of superconducting current-feeder system for the LHD

机译:LHD超导馈线系统的长期稳定运行

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A superconducting (SC) current-feeder system is used as the current transmission lines for the experimental fusion device, LRD. It consists of nine flexible SC bus lines with total length of 497 m, and nine pairs of gas-cooled current leads. To avoid the propagation of the ice on the leads, the temperature of the terminals had been kept in the range between 5 and 20 degrees C by the heaters. The measured voltage drops of all leads were less than 20 mV. The liquid helium levels of the leads and the sub-cooler tank will equalize by the siphon method. The total time of the coil excitations exceeds 3000 hours. We have demonstrated successfully that the SC current-feeder system was stable and easy to handle, and is useful for the SC experimental fusion device.
机译:超导(SC)电流馈送系统用作实验聚变设备LRD的电流传输线。它由9条总长497 m的柔性SC总线和9对气冷式电流引线组成。为了避免冰在导线上传播,通过加热器将端子的温度保持在5到20摄氏度之间。所有导线测得的电压降均小于20 mV。导线和过冷器罐的液氦水平将通过虹吸法进行补偿。线圈励磁的总时间超过3000小时。我们已经成功证明了SC电流馈电系统稳定且易于操作,可用于SC实验聚变设备。