The AC losses of the Inner Vertical (IV) coil have been measured during the Experiments on a Single Inner Vertical coil (EXSIV). The IV coils are the smallest poloidal coils of the Large Helical Device (LHD) and their inner and outer diameters are 3.2 m and 4.2 m, respectively. The coil consists of 16 pancake coils wound with the cable-in-conduit conductors (CICC) whose strands are NbTi/Cu without any surface coating. The AC losses were measured with a calorimetric method during excitation tests and current shut-off tests. In addition to the usual inter-strand coupling losses with short time constants, unexpected coupling losses were observed due to the coupling current of a long time constant
展开▼