The helical coils of the Large Helical Device are large scale pool-cooled superconducting coils. A conductor made of NbTi-Cu compacted strands and a pure Al stabilizer was developed to attain high cryostability. The design current of the conductor is 13.0 kA at 4.4 K, which produces a toroidal magnetic field of 3 T at a major radius of 3.9 m. The first excitation test up to 6.5 kA was conducted successfully is the beginning of the first cooling period. The higher excitations were tried in the second cooling period. The first propagation of a normal zone was observed when reaching 11.2 kA, and it recovered within 5 s. In the next step, a wide propagation occurred at 11.4 kA, and the quench detection system worked. The coils were designed to satisfy `cold-endu27 stability by using the recovery current measured in short samples, but a normal zone propagates at lower than the recovery current in the composite conductor stabilized by very low resistive metal
机译:大型螺旋装置的螺旋线圈是大型池冷却超导线圈。开发了由NbTi-Cu压实线束和纯Al稳定剂制成的导体,以实现较高的低温稳定性。导体的设计电流在4.4 K时为13.0 kA,在主半径3.9 m处产生3 T的环形磁场。在第一个冷却阶段的开始,成功进行了高达6.5 kA的首次励磁测试。在第二冷却阶段尝试了更高的激励。当达到11.2 kA时,观察到正常区域的首次传播,并在5 s内恢复。下一步,在11.4 kA处发生了广泛的传播,淬灭检测系统开始工作。通过使用短样品中测得的恢复电流将线圈设计为满足“冷端”稳定性,但正常区域的传播要低于电阻非常低的金属稳定的复合导体中的恢复电流

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号