首页> 外文OA文献 >Parabolic Trough Receiver Heat Loss and Optical Efficiency Round Robin 2015/2016
【2h】

Parabolic Trough Receiver Heat Loss and Optical Efficiency Round Robin 2015/2016

机译:抛物槽接收器的热损失和光效率Round Robin 2015/2016

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.
机译:2015/2016年,在五个机构之间使用五个接收器对抛物槽接收器的热损失和光学效率进行了轮循。在300°C至550°C的温度范围内,在三个筒式加热器测试台和一个焦耳加热测试台上进行了热损失测试。用两个光谱测试台和一个量热测试台进行光效率测试。热损失测试结果显示,在大多数温度和接收器下,标准偏差在6%到12%的范围内,而在100°C下,一个接收器的标准偏差为17%。光学效率针对实验室进行了归一化处理,根据接收器的不同,其标准偏差为0.3%至1.3%。