首页> 外文OA文献 >Determination of trace amounts of phosphorus in silicate materials by simultaneous inductively coupled plasma atomic emission spectrometry
【2h】

Determination of trace amounts of phosphorus in silicate materials by simultaneous inductively coupled plasma atomic emission spectrometry

机译:同时电感耦合等离子体原子发射光谱法测定硅酸盐材料中痕量磷

摘要

Inductively coupled plasma atomic emission spectrometry (ICP-AES) implemented on a simultaneous spectrometer was used for the determination of trace amounts of phosphorus in rocks, soils and sediments. Samples were decomposed by using a mixture of concentrated hydrofluoric, perchloric and nitric acid in Teflon beakers. Overlap of emissions from other elements present in the samples with the polychromator spectral line at 214.914 nm for phosphorus was studied. The corresponding inter-element coefficients for overlap correction were determined and the optimum position for background readings was established. The limit of determination achieved was 24 ppm referred to the solid sample. The proposed method was tested by applying it to the analysis of rock, soil and sediment certified reference materials, and determining its short-time precision and method precision, which turned out to be 0.24-0.68% and 1.70-4.16% (relative standard deviation), respectively.
机译:同步光谱仪上的电感耦合等离子体原子发射光谱法(ICP-AES)用于测定岩石,土壤和沉积物中的痕量磷。在特富龙烧杯中,使用浓氢氟酸,高氯酸和硝酸的混合物分解样品。研究了用多色仪光谱线在214.914 nm处的磷样品中其他元素的发射重叠。确定用于重叠校正的相应元素间系数,并确定背景读数的最佳位置。相对于固体样品,测定极限为24 ppm。通过将该方法应用于经岩石,土壤和沉积物认证的参考材料进行分析,并确定其短时精度和方法精度,分别为0.24-0.68%和1.70-4.16%(相对标准偏差),进行了测试。 ), 分别。