首页> 外文OA文献 >Analysis of 236U and plutonium isotopes, 239,240Pu, on the 1 MV AMS system at the Centro Nacional de Aceleradores, as a potential tool in oceanography
【2h】

Analysis of 236U and plutonium isotopes, 239,240Pu, on the 1 MV AMS system at the Centro Nacional de Aceleradores, as a potential tool in oceanography

机译:在国家航站楼1 MV AMS系统上分析236U和and同位素239,240Pu,作为海洋学中的潜在工具

摘要

The performance of the 1 MV AMS system at the CNA (Centro Nacional de Aceleradores, Seville, Spain) for 236U and 239,240Pu measurements has been extensively investigated. A very promising 236U/238U abundance sensitivity of about 3 × 10-11 has been recently achieved, and background figures for 239Pu of about 106 atoms were reported in the past. These promising results lead to the use of conventional low energy AMS systems for the analysis of 236U and 239Pu and its further application in environmental studies. First 236U results obtained on our AMS system for marine samples (sediments and water) are presented here. Results of two new IAEA reference materials (IAEA-410 and IAEA-412, marine sediments from Pacific Ocean) are reported. The obtained 236U/239Pu atom ratios, of 0.12 and 0.022, respectively, show a dependency with the contamination source (i.e. local fallout from the US tests performed at the Bikini Atoll and general fallout). The results obtained for a third IAEA reference material (IAEA-381, seawater from the Irish Sea), are also presented. In the following, the uranium and plutonium isotopic compositions obtained on a set of 5 intercomparison seawater samples from the Arctic Ocean provided by the ETH Zürich are discussed. By comparing them with the obtained results on the 600 kV AMS facility Tandy at the ETH Zürich, we demonstrate the solidity of the CNA technique for 236U/238U determinations at, at least, 7 × 10-10 level. Finally, these results are discussed in their environmental context.
机译:已经对CNA(西班牙塞维利亚的国家航空航天中心)的1 MV AMS系统的236U和239,240Pu测量性能进行了广泛研究。最近已经实现了非常有希望的约3×10-11的236U / 238U丰度灵敏度,并且过去报道了约106个原子的239Pu的背景数据。这些令人鼓舞的结果导致使用常规的低能耗AMS系统分析236U和239Pu及其在环境研究中的进一步应用。这里介绍了在我们的AMS系统上获得的用于海洋样本(沉积物和水)的最初236U结果。报告了两种新的国际原子能机构参考材料(IAEA-410和IAEA-412,来自太平洋的海洋沉积物)的结果。所获得的236U / 239Pu原子比分别为0.12和0.022,显示出与污染源的依赖性(即,在美国比基尼环礁进行的美国测试的局部沉降和一般的沉降)。还介绍了第三种国际原子能机构参考材料(IAEA-381,来自爱尔兰海的海水)获得的结果。在下文中,将讨论由苏黎世联邦理工学院提供的一组来自北冰洋的5个相互比较的海水样品获得的铀和p同位素组成。通过将它们与在ETHZürich的600 kV AMS设施Tandy上获得的结果进行比较,我们证明了CNA技术至少在7×10-10水平下用于236U / 238U测定的可靠性。最后,将在其环境范围内讨论这些结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com