首页> 外文OA文献 >Identification of technical problems affecting performance of DustTrak DRX aerosol monitors
【2h】

Identification of technical problems affecting performance of DustTrak DRX aerosol monitors

机译:确定影响DustTrak DRX气溶胶监测仪性能的技术问题

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

The TSI DustTrak Aerosol Monitor is a portable real-time instrument widely used for particulate matter (PM) mass concentrations monitoring. The aim of this work is to report on issues that have arisen from the use of the latest generation models DustTrak DRX (8533 and 8534) in the BREATHE, UPTECH and IMPROVE projects that can compromise data quality. The main issue we encountered was the occurrence of sudden artefact jumps in PM concentration, which can involve an increase from a few to some hundreds of μg·m− 3. These artefact jumps can sometimes be easily recognised (“obvious jump”), while others can be difficult to identify because the difference in the concentrations before and after the jump might be just few μg·m− 3 (“possible jump”) or because the jump is sustained over the whole monitoring period and only detectable if PM concentrations are simultaneously measured by other instruments (“hidden jump”). Moreover, in areas of relatively low PM levels, the unit reported concentration of 0 μg·m− 3 for ambient PM concentration or even negative concentration values which may seriously compromise the dataset. These data suggest issues with the detection of low PM concentrations, which could be due to an incorrect instrument offset or the factory calibration setting being inadequate for these PM concentrations. The upward and downward artefact jumps were not related to especially dusty or clean conditions, since they have been observed in many kinds of environments: indoor and outdoor school environments, subway stations and in ambient urban background air. Therefore, PM concentration data obtained with the TSI DustTrak DRX models should be handled with care and meticulously revised before being considered valid. To prevent these issues the use of auto zero module is recommended, so the DustTrak monitor is automatic re-zeroed without requiring the presence of any user. © 2017 Elsevier B.V.
机译:TSI DustTrak气溶胶监测仪是一种便携式实时仪器,广泛用于颗粒物(PM)质量浓度监测。这项工作的目的是报告在BREATHE,UPTECH和IMPROVE项目中使用最新一代模型DustTrak DRX(8533和8534)引起的问题,这些问题可能会损害数据质量。我们遇到的主要问题是PM浓度突然出现伪影跳跃,可能会从几微克增加到数百μg·m-3。这些伪影跳跃有时很容易识别(“明显跳跃”),而其他信号可能很难识别,因为跳跃之前和之后的浓度差异可能仅为几μg·m-3(“可能的跳跃”),或者因为该跳跃在整个监测期间都持续存在,并且只有在PM浓度为同时由其他仪器测量(“隐藏跳跃”)。此外,在PM水平相对较低的区域,该单位报告的环境PM浓度为0μg·m-3甚至是负浓度值,这可能会严重损害数据集。这些数据表明检测低PM浓度存在问题,这可能是由于仪器偏移不正确或工厂校准设置不适合这些PM浓度所致。向上和向下的伪影跳跃与多尘或清洁的条件无关,因为它们已在多种环境中观察到:室内和室外学校环境,地铁站以及城市背景空气中。因此,在使用TSI DustTrak DRX模型获得的PM浓度数据之前,应谨慎处理并进行仔细修改。为防止这些问题,建议使用自动归零模块,因此DustTrak监视器会自动归零,而无需任何用户在场。分级为4 +©2017 Elsevier B.V.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号