首页> 外文OA文献 >Influence of conductivity on cathodic protection of reinforced alkali-activated slag mortar using the finite element method
【2h】

Influence of conductivity on cathodic protection of reinforced alkali-activated slag mortar using the finite element method

机译:电导率对碱渣矿渣增强砂浆阴极保护的有限元影响

摘要

Cathodic protection (CP) is considered to be the only rehabilitation method for chloride-induced rebar corrosion in reinforced concrete structures. The protection current distribution depends on several parameters, such as the geometry and number of rebars and the concrete resistivity. In order to investigate the influence of concrete resistivity on the possibilities and limitations of rebar protection, this paper presents a numerical approach based on the finite element method (FEM) in conjunction with laboratory results to determine its impact on the CP of alkali-activated slag mortar. An ordinary Portland cement was also tested for comparative purposes. © 2009 Elsevier Ltd. All rights reserved.
机译:阴极保护(CP)被认为是钢筋混凝土结构中氯化物引起的钢筋腐蚀的唯一修复方法。保护电流分布取决于几个参数,例如钢筋的几何形状和数量以及混凝土的电阻率。为了研究混凝土电阻率对钢筋保护的可能性和局限性的影响,本文结合有限元方法提出了一种基于有限元方法(FEM)的数值方法,以确定其对碱活化矿渣CP的影响。砂浆。还对普通波特兰水泥进行了比较试验。 ©2009 ElsevierLtd。保留所有权利。