首页> 外文OA文献 >Discrimination by EIS of degradation mechanisms in lap joints of coated metal sheet
【2h】

Discrimination by EIS of degradation mechanisms in lap joints of coated metal sheet

机译:通过EIS鉴别涂层金属板搭接处的降解机理

摘要

The information derived from impedance diagrams obtained by using electrochemical sensors specifically designed for lap joints testing of coated metallic sheets is analyzed. The electrochemical sensors were made by means of steel or zinc sheets, uncontaminated or contaminated with variable amounts of sodium chloride, and overcoated with organic coatings. Such sensors show the effect of the nature of the metallic substrate, the underfilm saline contamination, and the relative humidity of the environment outside the lap joint. The results show that the information obtained from electrochemical impedance spectroscopy (EIS) on the behavior within the lap joints can be assessed by the criteria traditionally used for plain painted metal surfaces. By modeling the data, it is possible to discriminate between effects due to the organic coating and to the corrosion reaction at the metal-coating interface.
机译:分析了通过使用专门设计用于涂层金属板搭接测试的电化学传感器获得的阻抗图得出的信息。电化学传感器是通过钢板或锌板制成的,未受污染或被不同量的氯化钠污染,并覆盖有有机涂层。这样的传感器显示出金属基材的性质,薄膜下的盐水污染以及搭接接头外部环境的相对湿度的影响。结果表明,可以通过传统上用于涂漆金属表面的标准来评估从电化学阻抗谱(EIS)获得的有关搭接接头内行为的信息。通过对数据建模,可以在有机涂层和金属涂层界面的腐蚀反应之间进行区分。