Evaluation of PeneloPET Simulations of Biograph PET/CT Scanners

机译:传记PET / CT扫描仪的PeneloPET模拟评估

摘要

Monte Carlo (MC) simulations are widely used in positron emission tomography (PET) for optimizing detector design, acquisition protocols, and evaluating corrections and reconstruction methods. PeneloPET is a MC code based on PENELOPE, for PET simulations which considers detector geometry, acquisition electronics and materials, and source definitions. While PeneloPET has been successfully employed and validated with small animal PET scanners, it required a proper validation with clinical PET scanners including time-of-flight (TOF) information. For this purpose, we chose the family of Biograph PET/CT scanners: the Biograph True-Point (B-TP), Biograph True-Point with TrueV (B-TPTV) and the Biograph mCT. They have similar block detectors and electronics, but a different number of rings and configuration. Some effective parameters of the simulations, such as the dead-time and the size of the reflectors in the detectors, were adjusted to reproduce the sensitivity and noise equivalent count (NEC) rate of the B-TPTV scanner. These parameters were then used to make predictions of experimental results such as sensitivity, NEC rate, spatial resolution, and scatter fraction (SF), from all the Biograph scanners and some variations of them (energy windows and additional rings of detectors). Predictions agree with the measured values for the three scanners, within 7% (sensitivity and NEC rate) and 5% (SF). The resolution obtained for the B-TPTV is slightly better (10%) than the experimental values. In conclusion, we have shown that PeneloPET is suitable for simulating and investigating clinical systems with good accuracy and short computational time, though some effort tuning of a few parameters of the scanners modeled may be needed in case that the full details of the scanners studied are not available.
机译:蒙特卡洛(MC)仿真广泛用于正电子发射断层扫描(PET)中,用于优化检测器设计,采集协议以及评估校正和重建方法。 PeneloPET是基于PENELOPE的MC代码,用于PET模拟,其中考虑了检测器的几何形状,采集电子设备和材料以及源定义。虽然PeneloPET已成功应用于小型动物PET扫描仪并已通过验证,但它需要通过临床PET扫描仪(包括飞行时间(TOF)信息)进行正确验证。为此,我们选择了Biograph PET / CT扫描仪系列:Biograph True-Point(B-TP),带有TrueV的Biograph True-Point(B-TPTV)和Biograph mCT。它们具有类似的块检测器和电子设备,但是环和配置的数量不同。调整了模拟的一些有效参数,例如死区时间和探测器中反射镜的尺寸,以重现B-TPTV扫描仪的灵敏度和噪声当量计数(NEC)率。然后,这些参数用于预测所有Biograph扫描仪及其某些变体(能量窗口和探测器的附加环)的实验结果,例如灵敏度,NEC速率,空间分辨率和散射分数(SF)。预测与三台扫描仪的测量值一致,分别在7%(灵敏度和NEC率)和5%(SF)之内。 B-TPTV的分辨率比实验值稍好(10%)。总而言之,我们表明PeneloPET适合于以较高的准确性和较短的计算时间来模拟和研究临床系统,尽管在研究的扫描仪的全部细节被保留的情况下,可能需要一些努力来调整建模的扫描仪的一些参数。无法使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号