Background: The Control to Range Study was a multinational artificial pancreas study designed to assess the time spent in the hypo- and hyperglycemic ranges in adults and adolescents with type 1 diabetes while under closed-loop control. The controller attempted to keep the glucose ranges between 70 and 180mg/dL. A set of prespecified metrics was used to measure safety. Research Design and Methods: We studied 53 individuals for approximately 22h each during clinical research center admissions. Plasma glucose level was measured every 15-30min (YSI clinical laboratory analyzer instrument [YSI, Inc., Yellow Springs, OH]). During the admission, subjects received three mixed meals (1g of carbohydrate/kg of body weight; 100g maximum) with meal announcement and automated insulin dosing by the controller.Results: For adults, the mean of subjects' mean glucose levels was 159mg/dL, and mean percentage of values 71-180mg/dL was 66% overall (59% daytime and 82% overnight). For adolescents, the mean of subjects' mean glucose levels was 166mg/dL, and mean percentage of values in range was 62% overall (53% daytime and 82% overnight). Whereas prespecified criteria for safety were satisfied by both groups, they were met at the individual level in adults only for combined daytime/nighttime and for isolated nighttime. Two adults and six adolescents failed to meet the daytime criterion, largely because of postmeal hyperglycemia, and another adolescent failed to meet the nighttime criterion.Conclusions: The control-to-range system performed as expected: faring better overnight than during the day and performing with variability between patients even after individualization based on patients' prior settings. The system had difficulty preventing postmeal excursions above target range.
机译:背景:范围控制研究是一项跨国人工胰腺研究,旨在评估在闭环控制下成人和1型糖尿病青少年在降血糖和高血糖范围中花费的时间。控制器试图将葡萄糖范围保持在70至180mg / dL之间。使用一组预先指定的度量标准来度量安全性。研究设计和方法:在临床研究中心入院期间,我们研究了53个人,每个人大约22小时。每15-30分钟(YSI临床实验室分析仪[YSI,Inc.,Yellow Springs,OH])测量血浆葡萄糖水平。入院期间,受试者接受三餐混合餐(每公斤体重1克碳水化合物;最大100克碳水化合物),并宣布进餐并由控制者自动进行胰岛素剂量。结果:对于成年人,受试者的平均血糖水平为159mg / dL ,则平均71-180mg / dL的平均百分比为66%(白天为59%,过夜为82%)。对于青少年,受试者的平均葡萄糖水平平均值为166mg / dL,范围内的平均值百分比总体为62%(白天为53%,过夜为82%)。两组都满足了预先规定的安全标准,但成年人的个人水平仅在白天/夜间和孤立的夜间才达到。 2名成年人和6名青少年未达到白天标准,主要是由于餐后高血糖,而另一名青少年未达到夜间标准。结论:测距控制系统的表现符合预期:过夜表现优于白天,表现良好即使根据患者的先前设置进行个性化设置,患者之间的差异也很大。该系统很难防止餐后偏移超过目标范围。

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号