首页> 外文OA文献 >A Prospective Study of the Use of Fetal Intelligent Navigation Echocardiography (FINE) to Obtain Standard Fetal Echocardiography Views
【2h】

A Prospective Study of the Use of Fetal Intelligent Navigation Echocardiography (FINE) to Obtain Standard Fetal Echocardiography Views

机译:使用胎儿智能导航超声心动图(FINE)获得标准胎儿超声心动图的前瞻性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

OBJECTIVE: \ud\udTo evaluate the performance of Fetal Intelligent Navigation Echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volume datasets of the normal fetal heart in generating standard fetal echocardiography views.\ud\udMETHODS: \ud\udIn this prospective cohort study of patients with normal fetal hearts (19-30 gestational weeks), one or more STIC volume datasets were obtained of the apical four-chamber view. Each STIC volume successfully obtained was evaluated by STICLoop™ to determine its appropriateness before applying the FINE method. Visualization rates for standard fetal echocardiography views using diagnostic planes and/or Virtual Intelligent Sonographer Assistance (VIS-Assistance®) were calculated.\ud\udRESULTS: \ud\udOne or more STIC volumes (total n = 463) were obtained from 246 patients. A single STIC volume per patient was analyzed using the FINE method. In normal cases, FINE was able to generate nine fetal echocardiography views using: (1) diagnostic planes in 76-100% of the cases, (2) VIS-Assistance® in 96-100% of the cases, and (3) a combination of diagnostic planes and/or VIS-Assistance® in 96-100% of the cases.\ud\udCONCLUSION: \ud\udFINE applied to STIC volumes can successfully generate nine standard fetal echocardiography views in 96-100% of cases in the 2nd and 3rd trimesters. This suggests that the technology can be used as a method of screening for congenital heart disease
机译:目标:\ ud \ ud要评估将胎儿智能导航超声心动图(FINE)应用于正常胎儿心脏的时空图像相关(STIC)体积数据集的性能,以生成标准的胎儿超声心动图视图。\ ud \ ud方法:\ ud \ ud对胎儿心脏正常(妊娠19-30周)的患者进行的队列研究,获得了一个或多个心尖四腔视图的STIC体积数据集。在应用FINE方法之前,通过STICLoop™对成功获得的每个STIC体积进行评估,以确定其适当性。计算使用诊断平面和/或Virtual Intelligent Sonographer Assistance(VIS-Assistance®)进行的标准胎儿超声心动图视图的可视化率。\ ud \ ud结果:\ ud \ ud从246位患者中获得一个或多个STIC体积(总n = 463) 。使用FINE方法分析每位患者的单个STIC体积。在正常情况下,FINE能够使用以下方法生成九种胎儿超声心动图视图:(1)76-100%的病例使用诊断平面,(2)96-100%的病例使用VIS-Assistance®,以及(3)a诊断平面和/或VIS-Assistance®的组合可治疗96-100%的病例。第二和第三个三个月。这表明该技术可以用作筛查先天性心脏病的方法

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号