首页> 外文OA文献 >Tests of a scintillating-fibre tracking detector based on position-sensitive photomultiplier readout
【2h】

Tests of a scintillating-fibre tracking detector based on position-sensitive photomultiplier readout

机译:基于位置敏感光电倍增管读数的闪烁光纤跟踪探测器的测试

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

We report the results of measurements performed using a tracking detector based on 835 mu m scintillating fibres read out by two position-sensitive photomultipliers. A six-layer hodoscope consisting of 1.2 m long fibres has been built and tested using cosmic rays. Subsequently, two such hodoscopes have been assembled and tested using a hadron beam at the CERN PS. The efficiency per plane is found to be about 70% and the point resolution about 130 mu m. The signal-to-noise ratio is about 2.4 and is dominated by crosstalk in the position-sensitive photomultipliers.
机译:我们报告了使用跟踪检测器执行的测量结果,该检测器基于由两个位置敏感光电倍增器读出的835微米闪烁纤维。已建立了由1.2 m长的纤维组成的六层带状镜,并使用了宇宙射线进行了测试。随后,在CERN PS上使用强子射线束组装并测试了两台这样的全息仪。发现每平面的效率约为70%,点分辨率约为130微米。信噪比约为2.4,并且受位置敏感光电倍增管中的串扰影响。