首页> 外文OA文献 >Postfault Operation of an Asymmetrical Six-Phase Induction Machine With Single and Two Isolated Neutral Points
【2h】

Postfault Operation of an Asymmetrical Six-Phase Induction Machine With Single and Two Isolated Neutral Points

机译:具有单个和两个隔离的中性点的不对称六相感应电机的故障后操作

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The paper presents a study of postfault control for an asymmetrical six-phase induction machine with single and two isolated neutral points, during single open-phase fault. Postfault control is based on the normal decoupling (Clarke) transformation, so that reconfiguration of the controller is minimized. Effect of the single open-phase fault on the machine equations under this control structure is discussed. Different modes of postfault operation are analyzed and are further compared in terms of the achievable torque and stator winding losses. Validity of the analysis is verified using experimental results obtained from a six-phase induction motor drive prototype.
机译:本文提出了一种在单个开相故障期间具有单个和两个隔离中性点的不对称六相感应电机的故障后控制的研究。故障后控制基于常规解耦(Clarke)转换,因此控制器的重新配置减至最少。讨论了在这种控制结构下单相缺相故障对电机方程的影响。分析了故障后操作的不同模式,并就可获得的转矩和定子绕组损耗进行了比较。使用从六相感应电动机驱动器原型获得的实验结果验证了分析的有效性。