The influence of mixing methods and disinfectant on the physical properties of alginate impression materials

机译:混合方法和消毒剂对藻酸盐印模材料物理性能的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aims of this in vitro study were to quantify the effect of manual versus automatic mixing and of using a disinfectant on mechanical properties of three different alginate impression materials. Two of the three alginates tested were especially developed for orthodontic use: Orthotrace® and Orthofine® while the third was a conventional alginate CA37FS®. Alginates were mixed by hand or automatically using a Cavex alginate mixer II®. Mixing was performed at room temperature using tap water. The material was allowed to set in a water bath at 35°C (±1°C), simulating intra-oral setting conditions, and half of the samples were disinfected before testing. For each tested material, 10 standardized samples were used. The disinfectant used was the CavexImpreSafe® that has a bactericide, virucide, and fungicide function. The specimens were exposed for 3 minutes in a 3% solution and were then tested according to the ISO 1563: 1990 (E) standard specifications. Descriptive statistics and three-way analysis of variance were performed, and a 5% significance level was used for statistical analysis. Evaluation of tensile strength and elastic recovery of different alginate samples, hand versus automatical mixing or disinfected versus not disinfected, resulted in significant differences for all materials except for Orthofine®. Considering detail reproduction, all three alginates evaluated reproduced the 50-μm line successfully without interruption. The mixing method can significantly affect the elastic recovery and tensile strength of the alginates tested while the effect of using a disinfectant is less explicit.
机译:这项体外研究的目的是量化手动混合与自动混合以及使用消毒剂对三种不同藻酸盐印模材料的机械性能的影响。测试的三种藻酸盐中的两种专门为正畸用途开发:Orthotrace®和Orthofine®,而第三种是常规藻酸盐CA37FS®。手动或使用Cavex藻酸盐混合器II®自动混合藻酸盐。在室温下使用自来水进行混合。将该材料置于35°C(±1°C)的水浴中,模拟口内凝固条件,并在测试前对一半样品进行消毒。对于每种测试材料,使用10个标准化样品。使用的消毒剂是具有杀菌,杀病毒和杀菌功能的CavexImpreSafe®。将样品在3%的溶液中暴露3分钟,然后根据ISO 1563:1990(E)标准规范进行测试。进行描述性统计和方差的三向分析,并使用5%的显着性水平进行统计分析。评估不同藻酸盐样品的抗张强度和弹性回复率,手工对比自动混合,或消毒对比未消毒,除Orthofine®外,所有材料均存在显着差异。考虑到细节复制,评估的所有三种藻酸盐都成功地复制了50μm线,而没有间断。混合方法会显着影响所测试藻酸盐的弹性回复率和拉伸强度,而使用消毒剂的效果则不太明显。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号