摘要

The Reception Plate Method (RPM) as proposed by CEN/TC126/WG7 in EN 15657-1 estimatesthe structure-borne sound power injected from a (high mobility) vibrating source into a (lowmobility) concrete reception plate. This power level can be used as an input to predict structurebornesound pressure levels in buildings according to the calculation model in EN 12354-5. Tovalidate both the RPM and the prediction model, measurements are done using two sources: astandard ISO tapping machine and an industrial washing machine placed on three different bases.Both sources are successively placed on the RP and on a concrete floor of a standard impactsound test cell. The sound pressure level in the cell underneath is measured and compared withcalculated values. Difficulties in both the test method and the prediction model are investigated.
机译:由EN 15657-1中的CEN / TC126 / WG7提出的接收板方法(RPM)估计从(高迁移率)振动源注入到(低迁移率)混凝土接收板中的结构声功率。根据EN 12354-5中的计算模型,该功率水平可用作输入,以预测建筑物中的结构声压级。为了同时验证RPM和预测模型,需要使用两种来源进行测量:标准ISO攻丝机和放置在三个不同基座上的工业洗衣机,两个来源依次放置在RP和标准撞击声测试单元的混凝土地板上。测量下方单元中的声压级,并将其与计算值进行比较。研究了测试方法和预测模型的难点。