首页> 外文OA文献 >Interpreting and Implementing IEC 61850-90-5 Routed-Sampled Value and Routed-GOOSE Protocols for IEEE C37.118.2 Compliant Wide-Area Synchrophasor Data Transfer
【2h】

Interpreting and Implementing IEC 61850-90-5 Routed-Sampled Value and Routed-GOOSE Protocols for IEEE C37.118.2 Compliant Wide-Area Synchrophasor Data Transfer

机译:解释和实现适用于IEEE C37.118.2的广域同步相量数据传输的IEC 61850-90-5路由采样值和路由GOOSE协议

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Flexibility and adaptability requirements of future electric power grids for integrating DERs call for the developmentof Wide-Area Monitoring, Protection And Control (WAMPAC) applications, utilizing synchrophasor measurementsprovided by the Phasor Measurement Units (PMUs).IEEE C37.118 is the most utilized protocol for real-time exchange of synchronized phasor measurement data. In orderto full some gaps not addressed in IEEE C37.118, and also to harmonize with the IEC 61850 power utility automationstandard, the IEC 61850-90-5 technical report has been developed. IEC TR 61850-90-5 introduces a mechanism fortransfer of digital states and time synchronized phasor measurement data over wide-area networks between PhasorMeasurement Units (PMUs), Phasor Data Concentrators (PDCs) and WAMPAC applications in the context of IEC61850.This work interprets the IEEE C37.118.2 and IEC 61850-90-5 Routed-Sampled Value and Routed-GOOSE protocolsand describes the design and implementation of a library named Khorjin with the functionality of (1) an IEEE C37.118.2to IEC 61850-90-5 gateway and protocol converter and, (2) an IEC 61850-90-5 subscriber and trac parser.The main contribution of this work is the development of Khorjin library using only standard C libraries (i.e.independent from any operating system). This is allowing the use of the library in dierent platforms.The design requirements and functionality of the Khorjin library has been tested in the KTH SmarTS Lab Real-TimeHardware-in-the-Loop (HIL) simulation environment to assess its conformance to the functional requirements of IEEEC37.118.2 and IEC 61850-90-5 standards.
机译:未来电网集成DER的灵活性和适应性要求要求利用相量测量单元(PMU)提供的同步相量测量来开发广域监视,保护和控制(WAMPAC)应用.IEEE C37.118是使用最多的协议用于同步相量测量数据的实时交换。为了弥补IEEE C37.118中未解决的一些空白,并与IEC 61850电力实用程序自动化标准保持一致,已制定了IEC 61850-90-5技术报告。 IEC TR 61850-90-5引入了一种机制,用于在IEC61850范围内在相量测量单元(PMU),相量数据集中器(PDC)和WAMPAC应用之间通过广域网传输数字状态和时间同步相量测量数据。 IEEE C37.118.2和IEC 61850-90-5路由采样值和Routed-GOOSE协议,并描述了具有(1)IEEE C37.118.2到IEC 61850-90-5功能的名为Khorjin的库的设计和实现。网关和协议转换器,以及(2)IEC 61850-90-5用户和trac解析器。这项工作的主要贡献是仅使用标准C库(即独立于任何操作系统)开发Khorjin库。这允许在不同的平台上使用该库。Khorjin库的设计要求和功能已在KTH SmarTS Lab实时硬件在环(HIL)仿真环境中进行了测试,以评估其与功能的一致性。 IEEEC37.118.2和IEC 61850-90-5标准的要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号