Two phase pressure drops were measured for ammonia at a wide range of test conditions in two sizes of vertical mini channels. The test sections were made of stainless steel (AISI 316) tubes with internal diameter of 1.70 mm and 1.224 mm and a uniformly heated length of 245 mm. Experiments were conducted at three saturation temperatures of 23 °C, 33 °C and 43 °C, the heat flux ranging from 15 to 355 kW/m2 and the mass flux ranging from 100 to 500 kg/m2s. The effect of the heat flux, the mass flux, the vapour quality, the saturation temperature and the internal diameter on the two phase pressure drop are presented in this article. Some generalized two phase pressure drop correlations suggested for macro and micro scale channels are examined by comparing them with our experimental data. None of the examined correlations agreed well with the test data. A new correlation (modified form of Tran et al. correlation) is proposed which is able to predict the experimental data with MAD of 16% and 86% of the data is within ±30% range.
机译:在两种尺寸的垂直微型通道中,在广泛的测试条件下测量了氨的两相压降。测试部分由不锈钢(AISI 316)管制成,内径为1.70毫米和1.224毫米,均匀加热的长度为245毫米。实验是在23°C,33°C和43°C的三个饱和温度下进行的,热通量范围为15至355 kW / m2,质量通量范围为100至500 kg / m2s。本文介绍了热通量,质量通量,蒸气质量,饱和温度和内径对两相压降的影响。通过将它们与我们的实验数据进行比较,研究了一些建议用于宏观和微观尺度通道的广义两相压降相关性。所检查的相关性均未与测试数据完全吻合。提出了一种新的相关性(Tran等相关性的改进形式),它能够预测MAD为16%且86%的数据在±30%范围内的实验数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号