首页> 外文OA文献 >Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study
【2h】

Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study

机译:通过使用可移动磁铁的人工耳蜗,在1.5T和3T MRI处显着减少伪影:一项实验性的人体尸体研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

OBJECTIVE\ud\udCochlear implants (CIs) are standard treatment for postlingually deafened individuals and prelingually deafened children. This human cadaver study evaluated diagnostic usefulness, image quality and artifacts in 1.5T and 3T magnetic resonance (MR) brain scans after CI with a removable magnet.\ud\udMETHODS\ud\udThree criteria (diagnostic usefulness, image quality, artifacts) were assessed at 1.5T and 3T in five cadaver heads with CI. The brain magnetic resonance scans were performed with and without the magnet in situ. The criteria were analyzed by two blinded neuroradiologists, with focus on image distortion and limitation of the diagnostic value of the acquired MR images.\ud\udRESULTS\ud\udMR images with the magnet in situ were all compromised by artifacts caused by the CI. After removal of the magnet, MR scans showed an unequivocal artifact reduction with significant improvement of the image quality and diagnostic usefulness, both at 1.5T and 3T. Visibility of the brain stem, cerebellopontine angle, and parieto-occipital lobe ipsilateral to the CI increased significantly after magnet removal.\ud\udCONCLUSIONS\ud\udThe results indicate the possible advantages for 1.5T and 3T MR scanning of the brain in CI carriers with removable magnets. Our findings support use of CIs with removable magnets, especially in patients with chronic intracranial pathologies.
机译:目的\ ud \ ud人工耳蜗(CIs)是耳聋后个体和耳聋前儿童的标准治疗方法。这项人类尸体研究评估了在使用可移动磁体进行CI后1.5T和3T磁共振(MR)脑部扫描中的诊断有用性,图像质量和伪像。\ ud \ udMETHODS \ ud \ ud三个标准(诊断有用性,图像质量,伪像)分别为在五个带有CI的尸体头部中以1.5T和3T进行评估。在有和没有原位磁体的情况下进行了脑磁共振扫描。由两名不知情的神经放射科医生对标准进行了分析,重点是图像失真和所获得的MR图像的诊断价值的局限性。\ ud \ udRESULTS \ ud \ udMR磁体原位成像均受到CI造成的伪影的影响。去除磁体后,MR扫描显示出明显的伪影减少,在1.5T和3T时图像质量和诊断有用性都有显着改善。去除磁铁后,CI的脑干,小脑桥角和小脑顶枕叶的可见度显着增加。\ ud \ ud结论\ ud \ ud结果表明,在CI携带者中进行1.5T和3T MR扫描可能具有优势带有可拆卸的磁铁。我们的发现支持将CI与可移动磁体配合使用,特别是在患有慢性颅内病变的患者中。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号