首页> 外文OA文献 >A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry
【2h】

A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry

机译:液相色谱-串联质谱在两种不同的自动25-羟维生素D总免疫测定方法之间的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Introduction: Total 25-hydroxyvitamin D [25(OH)D] is the most reliable indicator of vitamin D status. In this study, we compared two automated immunoassay methods, the Abbott Architect 25-OH Vitamin D assay and the Roche Cobas Vitamin D total assay, with the liquid chromatography-tandem mass spectrometry (LC-MS/MS).Materials and methods: One hundred venous blood samples were randomly selected from routine vitamin D tests. Two of the serum aliquots were analyzed at the Abbott Architect i2000 and the Roche Cobas 6000’s module e601 in our laboratory within the same day. The other serum aliquots were analyzed at the LC-MS/MS in different laboratory. Passing-Bablok regression analysis and Bland-Altman plot were used to compare methods. Inter-rater agreement was analyzed using kappa (?) analysis. Results: The Roche assay showed acceptable agreement with the LC-MS/MS based on Passing-Bablok analysis (intercept: -5.23 nmol/L, 95% CI: -8.73 to 0.19; slope: 0.97, 95% CI: 0.77 to 1.15). The Abbott assay showed proportional (slope: 0.77, 95% CI: 0.67 to 0.85) and constant differences (intercept: 17.08 nmol/L; 95% CI: 12.98 to 21.39). A mean bias of 15.1% was observed for the Abbott and a mean bias of -14.1% was observed for the Roche based on the Bland-Altman plots. We found strong to nearly perfect agreement in vitamin D status between the immunoassays and LC-MS/MS. (?: 0.83 for Abbott, ?: 0.93 for Roche) using kappa analysis.Conclusion: Both immunoassays demonstrated acceptable performance, but the Roche Cobas assay demonstrated better performance than the Abbott Architect in the studied samples.
机译:简介:总25-羟基维生素D [25(OH)D]是维生素D状态的最可靠指标。在这项研究中,我们比较了两种自动免疫测定方法,即Abbott Architect 25-OH维生素D测定法和Roche Cobas维生素D总测定法与液相色谱-串联质谱法(LC-MS / MS)。从常规维生素D检查中随机抽取100个静脉血样本。当天在我们实验室的Abbott Architect i2000和Roche Cobas 6000的模块e601上分析了两个血清等分试样。其他血清等分试样在不同实验室的LC-MS / MS中进行分析。采用Passing-Bablok回归分析和Bland-Altman图比较方法。使用kappa(?)分析来分析评分者之间的一致性。结果:根据Passing-Bablok分析,罗氏测定法与LC-MS / MS表现出可接受的一致性(截距:-5.23 nmol / L,95%CI:-8.73至0.19;斜率:0.97,95%CI:0.77至1.15 )。 Abbott分析显示出成比例的比例(斜率:0.77,95%CI:0.67至0.85)和常数差(截距:17.08 nmol / L; 95%CI:12.98至21.39)。根据Bland-Altman图,Abbott的平均偏差为15.1%,Roche的平均偏差为-14.1%。我们发现免疫测定法和LC-MS / MS之间维生素D的状况达到了近乎完美的一致性。结论:两种免疫测定均显示出可接受的性能,但在所研究的样品中,Roche Cobas测定的性能优于Abbott Architect的含量(△:Abbott的0.83,Roche的0.93)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号