Introduction: Duplicate measurements can be used to describe the performance and analytical robustness of assays and to identify outliers. We performed about 235,000 duplicate measurements of nine routinely measured quantities and evaluated the observed differences between the replicates to develop new markers for analytical performance and robustness.Materials and methods: Catalytic activity concentrations of aspartate aminotransferase (AST), alanine aminotransferase (ALT), and concentrations of calcium, cholesterol, creatinine, C-reactive protein (CRP), lactate, triglycerides and thyroid-stimulating hormone (TSH) in 237,261 patient plasma samples were measured in replicates using routine methods. The performance of duplicate measurements was evaluated in scatterplots with a variable and symmetrical zone of acceptance (A-zone) around the equal line. Two quality markers were established: 1) AZ95: the width of an A-zone at which 95 % of all duplicate measurements were within this zone; and 2) OPM (outliers per mille): the relative number of outliers if an A-zone width of 5 % was applied.Results: The AZ95 ranges from 3.2% for calcium to 11.5% for CRP and the OPM from 5 (calcium) to 250 (creatinine). Calcium, TSH and cholesterol have an AZ95 of less than 5% and an OPM of less than 50.Conclusions: Duplicate measurements of a large number of patient samples identify even low frequencies of extreme differences and thereof defined outliers. We suggest two additional quality markers, AZ95 and OPM, to complement description of assay performance and robustness. This approach can aid the selection process of measurement procedures in view of clinical needs.
机译:简介:重复测量可用于描述测定的性能和分析的稳健性,并识别异常值。我们对9个常规量的样品进行了约235,000次重复测量,并评估了重复样品之间观察到的差异,以开发出分析性能和耐用性的新标记。材料和方法:天冬氨酸氨基转移酶(AST),丙氨酸氨基转移酶(ALT)和使用常规方法一式两份,对237,261例患者血浆中的钙,胆固醇,肌酐,C反应蛋白(CRP),乳酸,甘油三酸酯和促甲状腺激素(TSH)浓度进行了测量。在散点图中对重复测量的性能进行了评估,散点图在等距线周围具有可变且对称的接受区(A区)。建立了两个质量标记:1)AZ95:A区的宽度,所有重复测量的95%位于该区域内; 2)OPM(离群值/千分之一):如果应用A区宽度为5%,则离群值的相对数量。结果:AZ95的范围为钙的3.2%至CRP的11.5%,OPM的范围为5(钙)。到250(肌酐)。钙,TSH和胆固醇的AZ95低于5%,OPM低于50。结论:对大量患者样品的重复测量甚至可以发现极低频率的极端差异及其定义的异常值。我们建议使用另外两个质量标记AZ95和OPM,以补充对测定性能和稳健性的描述。考虑到临床需要,这种方法可以帮助选择测量程序。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号