Introduction: The aim of this study was to evaluate the stability of urine collected in preservative tubes for chemistry strip analyses and particle counting to determine whether the transport of urine samples with all of their constituents is possible. Materials and methods: 275 pathologic urine specimens were included. Each urine sample was evaluated after 4, 8, 12, 24, and 48 hours of storage in BD Vacutainer® Plus Urinalysis Preservative (BD UAP) tubes and compared with refrigeration at 4 °C. All analyses were peformed on H-800 and FUS-200 automatic modular urine analyzers (Dirui Industry, Changchun, China). The kappa coefficients (?), false positive (FP) and false negative (FN) rates were evaluated. ? > 0.8 was accepted as good agreement. Results: Haemoglobin (Hb), leucocyte esterase (LE), and protein (Pro) analyses should be performed within 4 hours, whereas glucose (Glc) was stable until the end of 48 hours in both storage conditions. Nitrite (Nit) was well preserved in BD UAP tubes for 24 hours but was stable only up to 8 hours at 4 °C. Bilirubin (Bil) had very high FN rates even at 4 hours in both conditions. The particle counting showed high FN rates for white blood cells (WBC) and red blood cells (RBC), whereas squamous epithelial cells (EC) were stable up to 8 hours in both conditions. Conclusions: Preanalytical requirements for both urine chemical strip analyses and particle counting in a unique sample were not met in either condition. Thus, the transfer of urine samples for centralization of urinalysis is not yet feasible.
机译:简介:这项研究的目的是评估在化学试纸分析和颗粒计数的防腐管中收集的尿液的稳定性,以确定是否可能运输所有成分的尿液样本。材料和方法:包括275个病理尿标本。在BDVacutainer®Plus尿液分析防腐剂(BD UAP)管中存储4、8、12、24和48小时后,对每个尿液样本进行评估,并与在4°C下的冷藏进行比较。所有分析均在H-800和FUS-200自动模块化尿液分析仪(中国长春迪瑞工业)上进行。评估卡伯系数(?),假阳性(FP)和假阴性(FN)比率。 ? > 0.8被认为是良好的协议。结果:血红蛋白(Hb),白细胞酯酶(LE)和蛋白质(Pro)分析应在4小时内进行,而葡萄糖(Glc)在两种储存条件下均稳定到48小时结束。亚硝酸盐(Nit)在BD UAP管中保存良好,可保存24小时,但在4°C下最多只能稳定8小时。胆红素(Bil)甚至在两种情况下都在4小时时都有很高的FN率。颗粒计数显示白细胞(WBC)和红细胞(RBC)的FN率高,而鳞状上皮细胞(EC)在两种情况下均稳定长达8小时。结论:在两种情况下,尿化学条分析和独特样品中颗粒计数的分析要求均未达到。因此,为了集中尿液分析而转移尿液样品尚不可行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号