首页> 外文OA文献 >The characterization of four gene expression analysis in circulating tumor cells made by Multiplex-PCR from the AdnaTest kit on the lab-on-a-chip Agilent DNA 1000 platform
【2h】

The characterization of four gene expression analysis in circulating tumor cells made by Multiplex-PCR from the AdnaTest kit on the lab-on-a-chip Agilent DNA 1000 platform

机译:在片上实验室Agilent DNA 1000平台上通过AdnaTest试剂盒的多重PCR进行循环肿瘤细胞中四种基因表达分析的表征

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Introduction: Nowadays, on-a-chip capillary electrophoresis is a routine method for the detection of PCR fragments. The Agilent 2100 Bioanalyzer was one of the first commercial devices in this field. Our project was designed to study the characteristics of Agilent DNA 1000 kit in PCR fragment analysis as a part of circulating tumour cell (CTC) detection technique. Despite the common use of this kit a complex analysis of the results from a long-term project is still missing. Materials and methods: A commercially available Agilent DNA 1000 kit was used as a final step in the CTC detection (AdnaTest) for the determination of the presence of PCR fragments generated by Multiplex PCR. Data from 30 prostate cancer patients obtained during two years of research were analyzed to determine the trueness and precision of the PCR fragment size determination. Additional experiments were performed to demonstrate the precision (repeatability, reproducibility) and robustness of PCR fragment concentration determination.Results: The trueness and precision of the size determination was below 3% and 2% respectively. The repeatability of the concentration determination was below 15%. The difference in concentration determination increases when Multiplex-PCR/storage step is added between the two measurements of one sample.Conclusions: The characteristics established in our study are in concordance with the manufacturer’s specifications established for a ladder as a sample. However, the concentration determination may vary depending on chip preparation, sample storage and concentration. The 15% variation of concentration determination repeatability was shown to be partly proportional and can be suppressed by proper normalization.
机译:简介:如今,片上毛细管电泳是检测PCR片段的常规方法。 Agilent 2100生物分析仪是该领域最早的商用设备之一。我们的项目旨在研究作为循环肿瘤细胞(CTC)检测技术一部分的PCR片段分析中安捷伦DNA 1000试剂盒的特性。尽管通常使用该工具包,但仍缺少对长期项目结果的复杂分析。材料和方法:将市售的Agilent DNA 1000试剂盒用作CTC检测(AdnaTest)的最后一步,用于确定Multiplex PCR产生的PCR片段的存在。分析了在两年研究中获得的30位前列腺癌患者的数据,以确定PCR片段大小测定的正确性和准确性。进行了额外的实验以证明PCR片段浓度测定的准确性(重复性,可重复性)和稳健性。结果:大小测定的真实性和准确性分别低于3%和2%。浓度测定的重复性低于15%。在一个样品的两次测量之间添加Multiplex-PCR /存储步骤时,浓度测定的差异会增加。结论:我们的研究建立的特征与针对梯子作为样品建立的制造商规范相一致。但是,浓度确定可能会根据芯片制备,样品存储和浓度而有所不同。浓度测定重复性的15%变化显示为部分成比例,可以通过适当的归一化加以抑制。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号