Introduction: The collected and shipped blood samples are exposed to a various extra-analytical factors prior to analysis. The aim of the study was to determine the stability of analytes in serum gel tubes and plain tubes exposed to a range of storage temperatures and times after centrifugation.Materials and methods: Fifteen healthy volunteers were recruited and venous blood was collected into four tubes, two with and two without gel separator. Analyzing the baseline samples in 30 min, all were stored at 4ºC or 24ºC for 6, 12, 18, 24, 30, 36, 48 and 72 hours and 1 week. Sixteen biochemi-cal anaytes were measured on each sample. Variations remained under the desirable bias conside-red as clinically insignificant.Results: On day three, most analytes remained stable including albumin, protein, creatinine, choles-terol, triglycerides, gamma-glutamyl transferase (GGT), alkaline phosphatase (ALP), alanine aminot-ransferase (ALT), creatine kinase (CK), lactate dehydrogenase (LD) regardless of tube types. Gluco-se concentration decreased markedly (P = 0.001) beginning from the first hours of storage in plain serum. The stability maximized for the analytes including glucose, total bilirubin, urea nitrogen (BUN), uric acid stored at 4 ºC in gel tubes. Aspartate aminotransferase (AST) activity increased significantly (P = 0.002) up to 48-h, however bias was not significant clinically. High density lipoprotein (HDL) con-centration was stable in gel tubes at 24 ºC, in plain tubes at 4 ºC stored up to 36-h.Conclusion: Serum gel or non-gel tubes might be used interchangeably for 11 analytes chilled or at 24 ºC, whereas some restrictions must be applied for glucose, AST, BUN, HDL, and uric acid.
机译:简介:收集和运输的血液样本在分析之前要暴露于各种分析外因素。这项研究的目的是确定离心后暴露于一定存储温度和时间的血清凝胶管和普通管中分析物的稳定性。材料和方法:招募十五名健康志愿者并将静脉血收集到四个试管中,两个有和两个没有凝胶分离器。在30分钟内分析基线样本,所有样本均在4ºC或24ºC下保存6、12、18、24、30、36、48、72小时和1周。在每个样品上测量了十六种生化分析物。结果:在第三天,大多数分析物保持稳定,包括白蛋白,蛋白质,肌酐,胆甾醇,甘油三酸酯,γ-谷氨酰转移酶(GGT),碱性磷酸酶(ALP),丙氨酸氨基转移酶(ALT),肌酸激酶(CK),乳酸脱氢酶(LD),无论管子类型如何。从在纯血清中储存的最初几个小时开始,葡萄糖酶浓度显着降低(P = 0.001)。对于分析物,包括葡萄糖,总胆红素,尿素氮(BUN)和尿酸,其在4ºC下储存在凝胶管中的稳定性最高。直至48小时,天冬氨酸转氨酶(AST)活性显着增加(P = 0.002),但临床上偏倚并不明显。高密度脂蛋白(HDL)浓度在24ºC的凝胶试管中,在4ºC的普通试管中可储存长达36小时,其浓度稳定。结论:血清凝胶或非凝胶试管可互换用于11种冷冻或室温的分析物24ºC,但是必须对葡萄糖,AST,BUN,HDL和尿酸施加一些限制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号