Temporal evolution of strut light intensity after implantation of bioresorbable polymeric intracoronary scaffolds in the ABSORB cohort B trial-an application of a new quantitative method based on optical coherence tomography.

机译:在ABSORB队列B试验中植入可生物吸收的聚合物冠状动脉内支架后,支撑光强度的时间变化-一种基于光学相干断层扫描的新定量方法的应用。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND\ud\udQuantitative light intensity analysis of the strut core by optical coherence tomography (OCT) may enable assessment of changes in the light reflectivity of the bioresorbable polymeric scaffold from polymer to provisional matrix and connective tissues, with full disappearance and integration of the scaffold into the vessel wall. The aim of this report was to describe the methodology and to apply it to serial human OCT images post procedure and at 6, 12, 24 and 36 months in the ABSORB cohort B trial.\ud\udMETHODS AND RESULTS\ud\udIn serial frequency-domain OCT pullbacks, corresponding struts at different time points were identified by 3-dimensional foldout view. The peak and median values of light intensity were measured in the strut core by dedicated software. A total of 303 corresponding struts were serially analyzed at 3 time points. In the sequential analysis, peak light intensity increased gradually in the first 24 months after implantation and reached a plateau (relative difference with respect to baseline [%Dif]: 61.4% at 12 months, 115.0% at 24 months, 110.7% at 36 months), while the median intensity kept increasing at 36 months (%Dif: 14.3% at 12 months, 75.0% at 24 months, 93.1% at 36 months).\ud\udCONCLUSIONS\ud\udQuantitative light intensity analysis by OCT was capable of detecting subtle changes in the bioresorbable strut appearance over time, and could be used to monitor the bioresorption and integration process of polylactide struts.
机译:背景\ ud \ ud通过光学相干断层扫描(OCT)对支撑杆芯进行定量光强度分析,可以评估生物可吸收性聚合物支架从聚合物到临时基质和结缔组织的光反射率的变化,并且支架完全消失和整合进入血管壁。本报告旨在描述该方法,并将其应用于ABSORB队列B试验中的术后6月,12、24和36个月的连续人OCT图像。\ ud \ ud方法和结果\ ud \ ud -域OCT回调,通过3D折叠视图确定了不同时间点的相应支撑。通过专用软件在支撑杆芯中测量了光强度的峰值和中值。在3个时间点对303个相应的支撑进行了连续分析。在序贯分析中,峰值光强度在植入后的前24个月逐渐增加,并达到平稳状态(相对于基线的相对差异[%Dif]:12个月时为61.4%,24个月时为115.0%,36个月时为110.7% ),而中位强度在36个月时仍保持增加(%Dif:12个月时为14.3%,24个月时为75.0%,36个月时为93.1%)。\ ud \ ud结论\ ud \ udOCT定量光强度分析能够检测生物可吸收支撑物外观随时间变化的细微变化,可用于监测聚丙交酯支撑物的生物吸收和整合过程。