Partial discharge (PD) is an electrical discharge, which does not bridge the electrodes between an insulation system completely under high electric field stress. PD events may affect the performance of insulation system because in long term, it may cause the breakdown of insulation system and failure of high voltage component due to repetition of PD events. In this work, two techniques of analysing PD data have been studied; the phase resolved partial discharge (PRPD) pattern and pulse sequential analysis (PSA) techniques. These two techniques were used to distinguish three main types of PD; they are corona, void and surface discharges. PD data were obtained from the measurement in high voltage laboratory in the University of Southampton, UK. In the end of the analysis, comparison between the PRPD and PSA methods was done to evaluate the advantages and disadvantages between the two techniques.
机译:局部放电(PD)是一种放电,它不会在高电场应力下完全桥接绝缘系统之间的电极。 PD事件可能会影响绝缘系统的性能,因为从长远来看,它可能会由于PD事件的重复而引起绝缘系统的故障和高压组件的故障。在这项工作中,研究了两种分析PD数据的技术:相分辨局部放电(PRPD)模式和脉冲顺序分析(PSA)技术。这两种技术用于区分PD的三种主要类型。它们是电晕,空隙和表面放电。 PD数据是从英国南安普敦大学高压实验室的测量中获得的。在分析的最后,对PRPD和PSA方法进行了比较,以评估这两种技术之间的优缺点。