摘要

For non-domestic buildings, the electricity consumption mostly comes from the usage of the air-conditioning system. Therefore, energy savings must be achieved to save cost, and hence there is a need to apply heat recovery technologies such as run-around coils, plate-to-plate heat exchangers, heat pipe heat exchangers and heat recovery wheels into the air conditioning and mechanical ventilation (ACMV) systems for these buildings. The examples of non-domestics buildings such as factories, hospitals and office buildings use more energy to supply fresh air into the space in comparison to residential buildings. According to Yau (2010), the changing of air must be at least 15 times hourly, and in certain cases such as the hospital, the prohibition of recirculation of the return air in operating theatres to ensure the air is clean from any virus or bacteria from the outdoor air is needed. The feasibility study on using heat recovery devices in a new medium-size building in University of Malaya was conducted. The potential of energy savings in the building was examined by studying the performance of the air-conditioning system. The heat recovery systems were analyzed, and the focus was on the energy savings of the HVAC system. The calculation of energy savings and payback periods were analyzed for the chosen heat recovery devices installed in the building. Based on the results obtained in this practical study, it is strongly recommended that heat recovery systems to be installed to reduce energy usages of air-conditioning systems operating in large buildings in the tropics.
机译:对于非民用建筑,电力消耗主要来自空调系统的使用。因此,必须实现节能以节省成本,因此需要将热回收技术(例如,旋绕盘管,板对板热交换器,热管热交换器和热回收轮)应用到空调和这些建筑物的机械通风(ACMV)系统。与住宅建筑相比,工厂,医院和办公楼等非住宅建筑使用更多的能量向该空间供应新鲜空气。根据丘(Yau,2010)的说法,换气必须每小时至少进行15次,在某些情况下,例如医院,禁止在手术室中回流空气,以确保空气中没有任何病毒或细菌需要室外空气。进行了在马来亚大学一座新的中型建筑中使用热回收装置的可行性研究。通过研究空调系统的性能,研究了建筑物节能的潜力。分析了热回收系统,重点是HVAC系统的节能。针对安装在建筑物中的选定热回收设备,分析了节能量和投资回收期的计算方法。根据此实际研究中获得的结果,强烈建议安装热回收系统,以减少在热带地区大型建筑物中运行的空调系统的能耗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号