In this paper hybrid anti-islanding algorithm for utility interconnection of distributed generation is proposed. This algorithm is based on two detection schemes; namely active and passive. Active detection algorithm generates disturbances at the output by Positive feedback and Continuous feedback signal injection which is based on DQ implementation. On the other hand passive detection algorithm detects islanding by measuring voltage, frequency, active and reactive power. Using total harmonic distortion (THD) as an additional parameter is proposed in this paper. Passive detection algorithm uses several types of loads such as resistive, capacitive and inductive connected in parallel and compares the performance of the algorithm in each case.
机译:本文提出了一种用于分布式发电效用互联的混合防孤岛算法。该算法基于两种检测方案:即主动和被动。主动检测算法通过基于DQ实现的正反馈和连续反馈信号注入在输出端生成干扰。另一方面,无源检测算法通过测量电压,频率,有功和无功功率来检测孤岛。本文提出使用总谐波失真(THD)作为附加参数。无源检测算法使用并联的电阻,电容和电感等几种负载,并比较每种情况下算法的性能。