首页> 外文OA文献 >Reducing Pump Power Consumption by 40 (1000 KW) Through Improved Pump Management in a Central Plant
【2h】

Reducing Pump Power Consumption by 40 (1000 KW) Through Improved Pump Management in a Central Plant

机译:通过改善中央工厂中的泵管理,将泵功率消耗降低40%(1000 KW)

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Chilled water system data collection and fieldmeasurements performed at the Central Utility Plantof Texas A&M University revealed that 30 - 50 % ofthe primary pump head is consumed by manual andautomatic valves being operated in a partially-openedcondition.A comprehensive analysis was performed todevelop an improved pump management schedule.The results show potential savings of up to 40% ofthe pump power consumption without any capitalinvestment. The optimized schedule is beingimplemented. This paper describes the method andpresents results of the analysis and implementation.
机译:在得克萨斯州A&M大学的中央公用事业厂进行的冷却水系统数据收集和现场测量表明,在部分打开的状态下操作的手动和自动阀消耗了主泵头的30%-50%,并进行了综合分析以开发改进的泵管理结果表明,无需任何资本投资,就可以节省多达40%的泵功率消耗。优化的时间表正在实施中。本文介绍了该方法,并给出了分析和实现的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号