Performance Evaluation of Hot Water Efficiency Plumbing System Using Thermal Valve

机译:使用热力阀的热水效率管道系统的性能评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In Korea two popular water distribution systems?the branch type and the separate type systems?have serious drawbacks. The branch type suffers from temperature instability while the separate type suffers from excessive piping. Neither of them re-circulates water. The system proposed in this paper utilizes a water-conserving piping system with a thermostat valve. This paper compares the proposed system with that of the separate type. Our findings show that the proposed system wastes less water. After re-circulating for 78-87 seconds, water is available at set point temperature (40?C). Also, when multiple water taps are in use, the average temperature deviation is less than 0.6?C. Moreover, the proposed system has 50% less flow rate than the separate type system.
机译:在韩国,两种流行的水分配系统(分支式和分离式系统)都有严重的缺陷。分支型遭受温度不稳定,而分离型遭受过多的管道运输。他们俩都没有再循环水。本文提出的系统利用带有恒温阀的节水管道系统。本文将提出的系统与单独的系统进行了比较。我们的发现表明,拟议的系统浪费更少的水。循环78-87秒后,可以在设定温度(40°C)下使用水。另外,当使用多个水龙头时,平均温度偏差小于0.6?C。此外,所提出的系统比单独类型的系统的流量少50%。