首页> 外文OA文献 >Analysis of Energy and Soft Dirt in an Urban Untreated Sewage Source Heat Pump System
【2h】

Analysis of Energy and Soft Dirt in an Urban Untreated Sewage Source Heat Pump System

机译:城市未经处理的污水源热泵系统中的能量和软污垢分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

When using urban untreated sewage as a cool and heat source of heat pump, it is unavoidable to form soft dirt. Based on the method of exergy, an analysis is given of the impact the dirt growth of a tube-shell sewage heat exchanger will have on transfer intensity, flow pressure drop and exergy loss. The conclusions are deduced by an example showing that the middle flow velocity is good for energy conservation and economical efficiency, and it is also needed to remove the dirt in time at low flow velocity.
机译:使用未经处理的城市污水作为热泵的冷热源时,不可避免地会形成软污垢。基于能值计算方法,分析了管壳式污水热交换器的污垢增长对传递强度,流压下降和能值损失的影响。通过一个实例得出结论,该实例表明中间流速有利于节能和经济效益,并且还需要在低流速下及时清除污垢。