An Analysis of International Energy Conservation Code (IECC)-Compliant Single-Family Residential Energy Use

机译:符合国际节能法规(IECC)的单家庭住宅能源使用情况分析

摘要

In 2001, the Texas State Senate passed Senate Bill 5 to reduce ozone levels by encouragingthe reduction of emissions of NOx that were not regulated by the Texas Natural ResourceConservation Commission, including point sources (power plants), area sources (such as residentialemissions), road mobile sources, and non-road mobile sources. For the building energy section, theTexas State Legislature adopted the 2000/2001 International Energy Conservation Code, asmodified by the 2001 Supplement, as the state's building energy code. The 2000/2001 IECC is acomprehensive energy conservation code that establishes a standard for the insulation levels,glazing and cooling and heating system efficiencies through the use of prescriptive andperformance-based provisions.Therefore, the purpose of this research is to improve the accuracy of a 2000/2001 IECCcompliantperformance simulation using the DOE-2.1e simulation program to investigate the energyperformance of a typical single-family house. To achieve this purpose, several objectives had to beaccomplished, including: 1) the development of an IECC-compliant simulation model, 2) thedevelopment and testing of specific improvements to the existing code-traceable model, 3) thecalibration and installation of sensors in a case-study house, 4) the validation of the improved simulation model with measured data from the case-study house, and 5) use the validated model tosimulate the energy-conserving features of single-family residences that cannot be simulated withexisting versions of the DOE-2.1e program.In order to create the code-traceable IECC-compliant simulation model, a base-case housesimulation was created and the results calibrated with measured energy and environmental datafrom the case-study house. This was done in order to obtain an improved simulation model thatwould more accurately represent the case-study building. The calibrated model was then used toverify the accuracy of the improved simulation methods against previous models and measured data.After validation of the new simulation methodologies, the IECC simulation model was usedto simulate different energy-conserving features for a single-family residence that could not besimulated with the previous version of the DOE-2 input file. Finally, areas for future work wereidentified in an effort to continue to improve the model.
机译:2001年,德克萨斯州参议院通过了参议院第5号法案,通过鼓励减少未被得克萨斯州自然资源保护委员会监管的NOx排放来降低臭氧水平,包括点源(发电厂),区域源(如住宅排放物),道路移动资源和非道路移动资源。在建筑能源方面,得克萨斯州立法机关采用了经2001年增补版修改的2000/2001年国际能源节约法规作为该州的建筑能源法规。 2000/2001 IECC是一项全面的节能法规,通过使用规范性的和基于性能的规定建立了隔热等级,玻璃,冷却和加热系统效率的标准,因此,本研究的目的是提高绝缘子的准确性。使用DOE-2.1e模拟程序进行2000/2001 IECC兼容的性能模拟,以研究典型的单户住宅的能源性能。为了达到这个目的,必须完成几个目标,包括:1)开发符合IECC的仿真模型,2)开发和测试对现有代码可追踪模型的特定改进,3)在传感器中校准和安装传感器。案例研究房,4)使用来自案例研究房的测量数据对改进的模拟模型进行验证,以及5)使用经过验证的模型来模拟无法使用现有版本进行模拟的单户住宅的节能特征DOE-2.1e程序。为了创建可跟踪代码的IECC兼容仿真模型,创建了基本案例房屋模拟,并使用来自案例研究房屋的测量的能源和环境数据对结果进行了校准。这样做是为了获得改进的仿真模型,该仿真模型可以更准确地表示案例研究大楼。然后使用校准后的模型来验证改进的仿真方法相对于以前的模型和实测数据的准确性。在验证了新的仿真方法之后,IECC仿真模型用于仿真单户住宅无法提供的不同节能特性。用DOE-2输入文件的先前版本模拟。最后,确定了未来工作的领域,以继续改进模型。

著录项

  • 作者

    Kim Seongchan;

  • 作者单位
  • 年度 2009
  • 总页数
  • 原文格式 PDF
  • 正文语种 en_US
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号