首页> 外文OA文献 >Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters
【2h】

Two phase mixing comparison, oil contamination comparison and manufacturing accuracy effect on calibration of slotted orifice meters

机译:两相混合比较,油污比较和制造精度对开孔孔板校准的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In previous studies the slotted orifice plate has demonstrated superior performance characteristics to those of the standard orifice plate. In this study, these comparisons are investigated further. The response characteristics of the slotted orifice plate to the standard orifice plate and V-Cone for two-phase flows of water and air at various qualities, flow rates, and pressures are shown visually. The effect of oil as it flows through a slotted orifice plate and standard orifice plate are visually documented. The effect of manufacturing accuracy on the slotted orifice plates is investigated as to the effect on the coefficient of discharge, percent change in pressure, and Reynolds number. The slotted orifice plate mixes two-phase flow better than the standard orifice plate and V-Cone. There is a manufacturing effect on the slotted orifice plates; the larger the area of the slots, the larger the discharge coefficient.
机译:在以前的研究中,开槽孔板已显示出优于标准孔板的性能特征。在这项研究中,将对这些比较进行进一步研究。可见地显示了开槽孔板对标准孔板和V型锥在水和空气两相流以各种质量,流量和压力的情况下的响应特性。目视记录油在流过开孔孔板和标准孔板时的影响。研究了制造精度对开孔孔板的影响,涉及对排放系数,压力变化百分比和雷诺数的影响。开缝孔板比标准孔板和V型锥更好地混合了两相流。开槽孔板上会产生制造效果。缝隙的面积越大,放电系数越大。

著录项

  • 作者

    Sparks Sara A.;

  • 作者单位
  • 年度 2004
  • 总页数
  • 原文格式 PDF
  • 正文语种 en_US
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号