It is the key question that how does the well group arrange for application of GWSHP system. Based on the fact that the water movement is the important factor of heat transfer on aquifer, this paper presents two steps analysis method and analyze the inter-well thermal transfixion, method as follows: (1) Forecast the least influence radius through calculating the thermal diffusion function of aquifer; (2) The analysis on the inter-well thermal transfixion makes use of the streamline analysis method and makes quantitative analysis of the effect that inter-well distance and flux make on it. It labors the well group arrangement and puts forward optimal scheme by means of the thermal diffusion and streamline simulation.