首页> 外文OA文献 >Response comparison of an optically stimulated luminescent dosimeter, a direct-ion storage dosimeter, and a thermoluminescence dosimeter
【2h】

Response comparison of an optically stimulated luminescent dosimeter, a direct-ion storage dosimeter, and a thermoluminescence dosimeter

机译:光激发发光剂量计,直接离子存储剂量计和热致发光剂量计的响应比较

摘要

This study was undertaken to compare the response of three dosimeters todifferent environments. Comanche Peak Nuclear Power Plant wants to replace thecurrent badge of record. The RaDos DIS-1 direct-ion storage dosimeter (DIS-1) and theLandauer InLight optically stimulated luminescence dosimeter (OSL) are the twocandidates for replacement of the Panasonic UD-802 thermoluminescence dosimeter(TLD). The dosimeters were compared in five categories: dose linearity, dose-ratelinearity, fade response, humidity response, and the angular dependence of thedosimeters.The major results include verified linear relationship evidence for dose and doserateand a better fade response for both the DIS-1 and OSL. The TLDs faded by 9.2%over a month and the DIS-1 and OSL faded by 4.2% and 1%, respectively. Following adose of 557.5 mrem, the dosimeters were exposed to different relative humidites. Thedose to the DIS-1 and OSL did not change drastically while the TLDs dose readout wasreduced by 10%. Finally, the angular dependence of the dosimeters was compared andthe worst responses were 66% at 90? in the horizontal orientation for the OSL and 1.7% at 90? in the horizontal orientation for the DIS-1. Based on the results of these tests theOSL seems like a more viable candidate for the new badge or record.
机译:进行这项研究以比较三种剂量计对不同环境的响应。科曼奇峰核电站希望替换当前的记录标志。 RaDos DIS-1直接离子存储剂量计(DIS-1)和Landauer InLight光学激发发光剂量计(OSL)是替代Panasonic UD-802热发光剂量计(TLD)的两个候选人。对剂量计进行了五类比较:剂量线性,剂量率线性,褪色响应,湿度响应和剂量计的角度依赖性。主要结果包括经验证的剂量和剂量率线性关系证据以及DIS-1均具有更好的褪色响应和OSL。 TLD在一个月内下降了9.2%,DIS-1和OSL分别下降了4.2%和1%。在剂量为557.5 mrem之后,剂量计暴露于不同的相对湿度。 DIS-1和OSL的剂量没有急剧变化,而TLDs的剂量读数降低了10%。最后,对剂量计的角度依赖性进行了比较,最差的响应在90?时为66%。 OSL的水平方向和90度时的1.7%?在DIS-1的水平方向上。根据这些测试的结果,OSL似乎是新徽章或记录的更可行的候选者。

著录项

  • 作者

    Hernandez Pete Jevon;

  • 作者单位
  • 年度 2009
  • 总页数
  • 原文格式 PDF
  • 正文语种 en_US
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利