首页> 外文OA文献 >Recommendations for 2009 IECC 15 Above Code Energy Efficiency Measures for Residential Buildings
【2h】

Recommendations for 2009 IECC 15 Above Code Energy Efficiency Measures for Residential Buildings

机译:2009年IECC的建议住宅建筑物能源效率高于标准的15%

摘要

In the 79th Legislature (2005) the Energy Systems Laboratory was required to develop three alternative methods for achieving 15% above-code energy savings in new residential, commercial and industrial construction. The Laboratory continues to work closely with code officials, energy raters, manufacturers, state officials and other stakeholders to develop cost effective energy efficiency measures.This report presents detailed information about the recommendations for achieving 15% above-code energy performance, which are based on the 2009 International Energy Conservation Code (IECC), for single-family residences across the State of Texas. To estimate above-code savings (%) of energy efficiency measures, total source energy savings from heating, cooling, lighting, equipment, and DHW were considered for emissions reductions determination. The recommendations were developed for three 2009 IECC climate zones in Texas along with simple payback calculations. This information is useful to homebuilders, utility demand side energy managers, homeowners and others who wish to construct residential buildings that exceed the minimum national energy code requirements.The analysis was performed using an ESL simulation model based on the DOE-2.1e simulation of a 2009 IECC code-compliant, single family residence and the appropriate TMY2 weather files for seventeen counties in Texas for which TMY2 data is available. According to 2009 IECC Climate Zone, seventeen counties were categorized into three climate zones: Climate Zone 2, 3, and 4, and the 2009 IECC code-compliance base-case models were constructed for each climate zone. Two options based on the choice of heating fuel type were considered: (a) natural gas (gas-fired furnace for space heating, and gas water heater for domestic water heating), and (b) electricity (heat pump for space heating, and electric water heater for domestic water heating).A total of eighteen measures based on the energy savings above the base-case house were selected. These measures include building envelope and fenestration, HVAC system, domestic hot water (DHW) system, lighting and renewable options. The implementation costs of each individual measure were also calculated along with simple payback calculations. These measures were then combined to achieve the total source energy savings of the group is 15% above the base-case 2009 code-compliant house. As a result, three example combinations were proposed for each base case ((a) electric/gas house and (b) all-electric house) in each climate zone. Each combination was formed to have a different payback period. Finally, the corresponding emissions savings of each combination were calculated based on the eGrid for Texas.
机译:在第79届立法机构(2005年)中,能源系统实验室被要求开发三种替代方法,以在新建的住宅,商业和工业建筑中实现节能15%以上的节能标准。实验室继续与规范官员,能源评估师,制造商,州官员和其他利益相关者紧密合作,以制定具有成本效益的能效措施。本报告提供了有关实现15%以上规范能效建议的详细信息。 2009年国际节能法(IECC),适用于德克萨斯州的单户住宅。为了估算节能措施的上述节省代码(%),考虑了供暖,制冷,照明,设备和DHW的总能源节省,以确定减排量。这些建议是针对德克萨斯州的三个2009 IECC气候区制定的,并进行了简单的投资回收期计算。该信息对于房屋建筑商,公用事业需求侧能源管理者,房主和其他希望建造超出国家最低能源法规要求的住宅的人很有用。分析是使用基于DOE-2.1e模拟的ESL模拟模型进行的。 2009年IECC规范,独户居住权以及适用于得克萨斯州17个县的TMY2气象文件,可提供TMY2数据。根据2009 IECC气候区,将17个县分为三个气候区:气候区2、3和4,并针对每个气候区构建了2009 IECC法规遵从性基础案例模型。考虑了两种基于供暖燃料类型选择的选择:(a)天然气(用于空间供暖的燃气炉和用于生活热水的燃气热水器),和(b)电力(用于空间供暖的热泵),以及家用热水器)。根据基本房屋上方的节能量,总共选择了18种措施。这些措施包括建筑围墙和开窗,HVAC系统,生活热水(DHW)系统,照明和可再生能源。还计算了每个单独措施的实施成本以及简单的回报计算。然后将这些措施结合起来,以使该组的总能源节省量比2009年基本规范合规房屋高出15%。结果,针对每个气候区域中的每个基本案例((a)电气/燃气房屋和(b)全电气房屋)提出了三个示例组合。每个组合的形成都有不同的投资回收期。最后,根据eGrid for Texas计算出每种组合的相应减排量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号