首页> 外文OA文献 >Trabecular metal tibial knee component still stable at 10 years : An RSA study of 33 patients less than 60 years of age
【2h】

Trabecular metal tibial knee component still stable at 10 years : An RSA study of 33 patients less than 60 years of age

机译:骨小梁金属胫骨膝盖组件在10年后仍保持稳定:一项针对33岁以下60岁以下患者的RSA研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Background and purpose - Total knee replacement (TKR) in younger patients using cemented components has shown inferior results, mainly due to aseptic loosening. Excellent clinical results have been reported with components made of trabecular metal (TM). In a previous report, we have shown stabilization of the TM tibial implants for up to 5 years. In this study, we compared the clinical and RSA results of these uncemented implants with those of cemented implants. Patients and methods - 41 patients (47 knees) aged 60 years underwent TKR. 22 patients (26 knees) received an uncemented monoblock cruciate-retaining (CR) tibial component (TM) and 19 patients (21 knees) received a cemented NexGen Option CR tibial component. Follow-up examination was done at 10 years, and 16 patients (19 knees) with TM tibial components and 17 patients (18 knees) with cemented tibial components remained for analysis. Results - 1 of 19 TM implants was revised for infection, 2 of 18 cemented components were revised for knee instability, and no revisions were done for loosening. Both types of tibial components migrated in the first 3 months, the TM group to a greater extent than the cemented group. After 3 months, both groups were stable during the next 10 years. Interpretation - The patterns of migration for uncemented TM implants and cemented tibial implants over the first 10 years indicate that they have a good long-term prognosis regarding fixation
机译:背景与目的-在年轻患者中使用胶结组件进行全膝关节置换(TKR)效果较差,这主要是由于无菌性松动所致。用小梁金属(TM)制成的组件已报告了极好的临床结果。在以前的报告中,我们显示了TM胫骨植入物可以稳定长达5年。在这项研究中,我们比较了这些非骨水泥植入物与骨水泥植入物的临床和RSA结果。患者和方法-41名60岁的患者(47膝)接受了TKR。 22例患者(26膝)接受了未粘固的单块交叉保留(CR)胫骨组件(TM),19例患者(21膝)接受了固结的NexGen Option CR胫骨组件。在10年时进行了随访检查,并保留了16例(19膝)TM胫骨组件和17例(18膝)胶合胫骨组件以进行分析。结果-对19种TM植入物中的1种进行了感染修复,对18种胶结部件中的2种进行了膝盖不稳定性修复,对松动没有进行任何修复。两种类型的胫骨组件均在头3个月内迁移,TM组比骨水泥组更大。 3个月后,两组在接下来的10年中保持稳定。解释-未粘合的TM植入物和粘合的胫骨植入物在最初的10年中的迁移模式表明,它们在固定方面具有良好的长期预后

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号