Measuring 3-dimensional tooth movement with a 3-dimensional surface laser scanner

机译:使用三维表面激光扫描仪测量三维牙齿移动

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Introduction: Our aims in this study were to (1) develop a method of measuring 3-dimensional (3D) tooth movement using a 3D surface laser scanner, (2) test the accuracy of this method, and (3) compare the measurements with those from cephalometric radiographs. Methods: A method of superimposing pretreatment and posttreatment models on the palatal rugae was developed, and an experimental model was prepared to evaluate the accuracy and reliability of the laser scanner. Records were obtained from a prospective longitudinal randomized clinical trial evaluating anchorage loss with headgears and midpalatal osseointegrated implants as a source of anchorage in Chesterfield, United Kingdom. The pretreatment and posttreatment study models were analyzed by using a 3D laser scanner to measure the 3D tooth movement. Results: The laser scanner was accurate to 0.0235 mm for anteroposterior measurements and 0.0071 mm for buccolingual movements for every 0.5 mm of movement. The study model analysis showed that mesial molar movements were 1.38 mm on the right side and 1.11 mm on the left side for the implant group, and 2.24 mm on right side and 1.63 mm on left side for the headgear group, with no statistically significant difference between the groups. The results for vertical movement of molars showed extrusion on both sides in both groups but no statistically significant difference between the groups. In the transverse plane, the results were not statistically significantly different between the groups. The results from superimposition of lateral cephalograms were similar to those obtained from the scanner. Conclusions: The 3D laser scanner provides accurate and reliable measurements of tooth displacement and can be considered an alternative to cephalometric radiographs. © 2009 American Association of Orthodontists.
机译:简介:我们在本研究中的目标是(1)使用3D表面激光扫描仪测量三维(3D)齿移动的方法,(2)测试该方法的准确性,(3)比较测量来自头部测量射线照片的人。方法:开发了一种叠加腭振动上的预处理和后处理模型的方法,准备了一种实验模型来评估激光扫描仪的准确性和可靠性。从前瞻性纵向随机临床试验中获得记录,评估锚固损失与头饰和中鼠骨整合植入物作为英国切斯特菲尔德的锚地来源。通过使用3D激光扫描仪测量3D齿移动来分析预处理和后处理模型。结果:激光扫描仪精确至0.0235 mm,用于前后测量值,为每0.5毫米运动的冲击运动进行0.0071毫米。研究模型分析表明,右侧的间隙摩尔运动为1.38毫米,左侧的左侧1.11mm,右侧2.24毫米,头盔组左侧1.63毫米,没有统计学意义在组之间。臼齿垂直运动的结果显示两组两侧的挤出,但组之间没有统计学上显着差异。在横向平面中,这些结果在组之间没有统计学显着差异。横向头部叠加的结果与从扫描仪获得的结果类似。结论:3D激光扫描仪提供精确可靠的牙齿位移测量,并且可以被认为是头部测量射线照片的替代方案。 ©2009美国东正教协会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号