首页> 外文OA文献 >Added Value of Digital Breast Tomosynthesis Combined with Digital Mammography According to Reader Agreement: Changes in BI-RADS Rate and Follow-Up Management
【2h】

Added Value of Digital Breast Tomosynthesis Combined with Digital Mammography According to Reader Agreement: Changes in BI-RADS Rate and Follow-Up Management

机译:根据读者协议,结合数字乳腺X线摄影的数字乳房断层合成的附加价值:双向射线率的变化和后续管理

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

BACKGROUND:udThe aim of this study was to evaluate the added value of digital breast tomosynthesis (DBT) when combined with digital mammography (DM) in BI-RADS assessment and follow-up management.udMETHODS:udFrom February 2014 to January 2015, 214 patients underwent DM and DBT, acquired with a Siemens Mammomat Inspiration unit. 2 expert readers independently reviewed the studies in 2 steps: DM and DM+DBT, according to BI-RADS rate. Patients with BI-RADS 0, 3, 4, and 5 were recalled for work-up. Inter-reader agreement for BI-RADS rate and work-up rate were evaluated using Cohen's kappa.udRESULTS:udInter-reader agreement (κ value) for BI-RADS classification was 0.58 for DM and 0.8 for DM+DBT. DM+DBT increased the number of BI-RADS 1, 2, 4, 5 and reduced the number of BI-RADS 0 and 3 for both readers compared to DM alone. Regarding work-up rate agreement, κ was poor for DM and substantial (0.7) for DM+DBT. DM+DBT also reduced the work-up rate for both Reader 1 and Reader 2.udCONCLUSION:udDM+DBT increased the number of negative and benign cases (BI-RADS 1 and 2) and suspicious and malignant cases (BI-RADS 4 and 5), while it reduced the number of BI-RADS 0 and 3. DM+DBT also improved inter-reader agreement and reduced the overall recall for additional imaging or short-interval follow-up.
机译:背景: udThe瞄准这项研究的是当与BI-RADS评估和后续管理数字化乳腺X线摄影(DM)相结合,以评估数字乳房X射线照相组合的增值(DBT) udMETHODS: udFrom 2014年2月至2015年1月,214例患者接受DM和DBT,具有西门子MAMMOMAT启示单元获取。 2名专家读者独立审查2个步骤的研究:DM和DM + DBT,根据BI-RADS率。患者BI-RADS 0,3,4,5被召回的后处理。为BI-RADS率和工作速率高达使用科恩kappa评估各国读者协议 udRESULTS: udInter阅读器协议(κ值)BI-RADS分级为0.58 DM和0.8 DM + DBT。 DM + DBT增加BI-RADS的1,2,4,5的数量和减少BI-RADS 0和3单独相比DM两个读卡器数量。对于工作了利率协议,κ差为DM + DBT DM和实质性的(0.7)。 DM + DBT也降低了后处理速率都读卡器1和阅读器2 udCONCLUSION: udDM + DBT增加的负和良性例(BI-RADS 1和2)和可疑的和恶性的情况下(BI-RADS数图4和5),而其降低BI-RADS 0和3 DM + DBT也改善阅读器间协议的数量,并减少了总的召回额外成像或短的时间间隔的后续。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号