首页> 外文OA文献 >Experimental Investigations Of Oxygen Stripping from Feed Water in a Spray and Tray Type De-Aerator
【2h】

Experimental Investigations Of Oxygen Stripping from Feed Water in a Spray and Tray Type De-Aerator

机译:喷雾盘式除氧器给水脱氧实验研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The influence of various parameters on oxygen stripping for a two stage spray and tray type de-aerator is analyzed experimentally. It is observed that increasing the mass flowudrate of water leads to an increase in heat and mass transfer coefficients in both stages. There is no significant influence of de-aerator pressure and length of the second stage on the heat transfer coefficients in the range tested. The increase in de-aerator pressure enhances the mass transfer coefficient by 14 percent, whereas the increase in length of the second stage has no significant influence. The empirical correlations available in theudliterature predict the mass transfer coefficients satisfactorily in the experimental range tested. The total length of the de-aerator is a significant parameter influencing the quantity of oxygen removed from the feed water.ud
机译:实验分析了两参数喷雾塔盘式除氧器中各种参数对氧气汽提的影响。可以观察到,增加水的质量流量/净水量会导致两个阶段的传热系数和传质系数增加。在测试范围内,除气器压力和第二级长度对传热系数没有显着影响。除氧器压力的增加使传质系数提高了14%,而第二级长度的增加没有显着影响。在文献中可获得的经验相关性可以在测试的实验范围内令人满意地预测传质系数。除氧器的总长度是影响从给水中去除的氧气量的重要参数。