Air conditioning is a process by which air is cooled or heated, cleaned or filtered, and circulated or recirculated. Air conditioning had become a standard option on most vehicle for enhancing comfort and safety. Regarding to this situation, an experiment and analysis need to be done to analyze the coefficient of performance (COP) of Proton Waja car during variable compressor speed and variable refrigerant weight. There are four locations of temperature measurement were selected in order to analyze the system. These locations are at the inlet and outlet of the compressor, the outlet of the condenser, and the inlet of the evaporator, respectively. The pressure was measured at the low pressure side and high pressure side which are at the outlet of the evaporator and inlet of the condenser, respectively. Before experimenting, a Statistica Software was used to reduce the error of experiment, and this software can design the experiment order. Besides that, the result from manual calculation can be validate with the result from Statistica Software. All of the parameters are measured during the cycle and were analyzed by using the properties table for refrigerant-134a and the p-h diagram for refrigerant-134a in order to determine the heat rejection, cooling effect, work of compressor and the coefficient of performance (COP) of the air conditioning system. The heat rejection, cooling effect, work of compressor, and the COP of the air conditioning system were investigated at variable speed of compressor and variable weight of refrigerant. The COP of the system was decreasing as the increasing of time and the compressor speed. It is also similar to COP of the system during the increasing of refrigerant weight and time in other experiment.
机译:空调是一种过程,通过该过程,空气被冷却或加热,清洁或过滤,然后循环或再循环。为了提高舒适性和安全性,空调已成为大多数车辆的标准选择。针对这种情况,需要进行实验和分析,以分析质子瓦哈汽车在可变的压缩机转速和可变的制冷剂重量下的性能系数(COP)。为了分析系统,选择了四个温度测量位置。这些位置分别在压缩机的入口和出口,冷凝器的出口和蒸发器的入口。在分别在蒸发器的出口和冷凝器的入口的低压侧和高压侧测量压力。实验前,使用Statistica软件减少实验误差,该软件可以设计实验顺序。除此之外,手动计算的结果可以用Statistica Software的结果进行验证。在循环过程中测量所有参数,并使用制冷剂134a的特性表和制冷剂134a的ph图进行分析,以确定排热,冷却效果,压缩机的工作情况以及性能系数(COP)。 )的空调系统。研究了在压缩机转速变化和制冷剂重量变化的情况下,空调系统的散热,冷却效果,压缩机的工作情况以及COP。随着时间和压缩机速度的增加,系统的COP逐渐减小。在其他实验中,随着制冷剂重量和时间的增加,它也类似于系统的COP。

著录项

  • 作者

    Mohamad Nadzif Zahirudin;

  • 作者单位
  • 年度 2009
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号