This paper presents two grid-connected photovoltaic (PV) systems (monocrystalline silicon, c-Si; copper–indium–diselenide; CIS) situated on the rooftop of the solar lab building in the National University of Malaysia, southwestern Malaysia. Various parameters were used to analyze the system performance; including array yield, final yield, capacity factor, and performance ratio. The recordings were noted down under the actual climatic conditions for an entire year. The variables of energy cost and payback period were also considered to calculate the economic feasibility of the system. Variations in the final yield of CIS were as low as 2.98 h/day in July to the highest value of 4.31 h/day in March. The final yield for c-Si power plant ranged from 2.92 h/day in July to 4.14 h/day in March. The calculated capacity factors for CIS and c-Si power plants were 15.6% and 14.4%, respectively, in July as the worst value, and 21.12% and 20.2%, respectively, in March as the best value. In the case of CIS power plant, the performance ratio ranges from 63.8 in July to 84.12 in March, and for c-Si power plant, it ranges from 59.92 in July to 79.14 in March. The energy cost and the payback period of the suggested system were evaluated as 0.045 USD/kWh and 28.44 years, respectively. Finally, this study provides valuable information for those who are interested in PV system installation in the tropical zones
机译:本文介绍了位于马来西亚西南部国立大学太阳能实验室大楼屋顶上的两个并网光伏(PV)系统(单晶硅,c-Si;铜-铟-二硒化物; CIS)。使用各种参数来分析系统性能;包括阵列成品率,最终成品率,容量因子和性能比。记录记录了全年的实际气候条件。还考虑了能源成本和投资回收期的变量,以计算系统的经济可行性。独联体最终产量的变化在7月低至2.98小时/天,在3月最高达到4.31小时/天。 c-Si电厂的最终产量从7月的2.92小时/天到3月的4.14小时/天不等。 CIS和c-Si电厂的计算出的容量因子,最差值分别为7月的15.6%和14.4%,3月的最优值分别为21.12%和20.2%。就独联体电厂而言,性能比范围从7月的63.8到3月的84.12,对于c-Si电厂,其性能比率从7月的59.92到3月的79.14。建议系统的能源成本和投资回收期分别为0.045美元/千瓦时和28.44年。最后,这项研究为那些对热带地区的光伏系统安装感兴趣的人提供了有价值的信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号