首页> 外文OA文献 >Simulation Study on Electrical Resistance Tomography using Metal Wall for Bubble Detection
【2h】

Simulation Study on Electrical Resistance Tomography using Metal Wall for Bubble Detection

机译:金属壁气泡检测电阻层析成像的仿真研究

摘要

Industrial process pipelines are mostly known to be constructed from metal which is a conducting material. Bubbles or gas detection are crucial in facilitating the bubble columns performance. By employing the Electrical Resistance Tomography (ERT) technique, a simulation study using COMSOL has been conducted to investigate the effect of excitation strategy, bubble sizes and locations towards the metal wall system. As for the current excitation strategy, conducting boundary protocol has to be applied when it comes to metallic vessel to overcome the grounding effect. Bubbles with a greater size than 2 mm and especially the one that is located near the wall boundary are much easier to detect. Further potential improvements to the current design and image reconstruction of the ERT system are desirable to improve the detection of small and centred bubble.
机译:众所周知,工业过程管道是由金属制成的,金属是一种导电材料。气泡或气体检测对于促进气泡塔性能至关重要。通过使用电阻层析成像(ERT)技术,已进行了使用COMSOL的模拟研究,以研究激发策略,气泡大小和位置对金属壁系统的影响。对于当前的励磁策略,当涉及金属容器时,必须应用传导边界协议以克服接地效应。大于2毫米的气泡,尤其是位于壁边界附近的气泡更容易检测。期望对ERT系统的当前设计和图像重建进行进一步的潜在改进,以改善对小而集中的气泡的检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号