首页> 外文OA文献 >Performance of solar air-conditioning system using heat pipe evacuated tube collector
【2h】

Performance of solar air-conditioning system using heat pipe evacuated tube collector

机译:热管真空管集热器的太阳能空调系统性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This is a study on the performance of solar air-conditioning system using heat pipe evacuated tube collector. The objective of this project is to analysis the performance solar air-conditioning system by determining the solar collector efficiency, coefficient of performance (COP) of the absorption chiller, and overall system efficiency and also the electrical energy consumption and operation cost for the system and compare it with the conventional air-conditioning system from the previous case study. The existing solar air-conditioning system is not competitive with electricity driven air-conditioning system because of their high investment and installation cost. Its overall thermal energy conversion efficiency is relatively low, and from an economical point of view, solar cooling and refrigeration are not competitive with the conventional systems. The experiment is conducted at Solar District Cooling Sdn. Bhd and data collected from building automation system for 30 days from 1st-30th June 2010. The data analysed using the theoretical analysis and plotted in graph to discuss about it. The solar collector efficiency varies from 50 to 80% during day time and stored energy can be used during night time. The COP varies from 2.961-2.966 and the overall system efficiency is from 30 to 50%. The investment cost is higher and electrical consumption is relatively lower than conventional air-conditioning system. The economical view is profitable after 18 years and 7 months of installation and environmental view is green energy without pollution. Although all the above findings refer to a particular application in Malaysia, the similar results can be obtained in the country with high solar availability. Finally by considering the problem of pollution of the planet due to the burning of fossil fuels the adoption of solar energy to power absorption chillers, even with marginal economic benefits, should not be underestimated.
机译:这是对使用热管真空管集热器的太阳能空调系统性能的研究。该项目的目的是通过确定太阳能收集器的效率,吸收式制冷机的性能系数(COP),系统的整体效率以及系统和系统的电能消耗和运行成本来分析太阳能空调系统的性能。将其与先前案例研究中的常规空调系统进行比较。现有的太阳能空调系统由于其高投资和安装成本而不能与电动空调系统竞争。其总的热能转换效率相对较低,并且从经济的角度来看,太阳能冷却和制冷与常规系统不具有竞争力。该实验在Solar Area Cooling Sdn。 Bhd和从楼宇自动化系统收集的数据,从2010年6月1日至30日为期30天。使用理论分析对数据进行分析,并绘制在图表中进行讨论。白天,太阳能集热器的效率从50%到80%不等,夜间可以使用存储的能量。 COP在2.961-2.966之间变化,整个系统效率为30%至50%。与传统的空调系统相比,投资成本较高且耗电量相对较低。安装18年零7个月后,经济观点是有利可图的,而环境观点是无污染的绿色能源。尽管以上所有发现均针对马来西亚的特定应用,但在太阳能利用率高的国家也可以获得类似的结果。最后,通过考虑由于化石燃料燃烧而造成的地球污染问题,即使具有边际经济效益,也不应低估采用太阳能作为动力吸收式制冷机的可能性。

著录项

  • 作者

    Mahendran Moorthy;

  • 作者单位
  • 年度 2010
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号