首页> 外文OA文献 >Numerical Study on the Effect of Geometrical Parameters on the Performance of Vortex Tube Cooling Device Using Simflow
【2h】

Numerical Study on the Effect of Geometrical Parameters on the Performance of Vortex Tube Cooling Device Using Simflow

机译:Simflow对几何参数对涡流管冷却装置性能影响的数值研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Vortex tube is a simple device which can separate room temperature compressed gas into the cold and hot flow. The performance of vortex tube is mainly affected by its geometrical parameters. In this study, the parameters are focused on cold outlet diameter and hot tube length. The objective of this study is to investigate the effect the cold outlet diameter and hot tube length in the range of 4-5 mm and 175-194 mm, respectively, when the inner diameter of vortex tube is 10 mm. The numerical investigation was carried using SIMFLOW 2.1 to predict the performance of vortex tube. The results show that 4 mm cold outlet diameter and 175 mm hot tube length is the optimum parameter for 10 mm inner tube diameter of the vortex tube.
机译:涡流管是一种简单的设备,可以将室温下的压缩气体分离成冷热流。涡流管的性能主要受其几何参数影响。在这项研究中,参数集中在冷出口直径和热管长度上。本研究的目的是研究当涡流管内径为10 mm时,冷出口直径和热管长度分别在4-5 mm和175-194 mm范围内的影响。使用SIMFLOW 2.1进行了数值研究,以预测涡流管的性能。结果表明,对于涡流管内管直径为10 mm,冷出口直径为4 mm,热管长度为175 mm是最佳参数。