Comparison of chemiluminescent microparticle immunoassay (CMIA) with electrochemiluminescence immunoassay (ECLIA) for Carcinoembryonic antigen (CEA)

机译:化学发光微粒免疫测定(CMIA)与电化学发光免疫测定(CMIA)对甲基丙烯醛抗原(CEA)

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Introduction: Carcinoembryonic antigen (CEA) is used for monitoring of disease progression and treatment response in cancer patients. Our aim was to compare the performance of chemiluminescent microparticle immunoassay (CMIA) with electrochemiluminescence immunoassay (ECLIA) for CEA.Methods: A total of 115 samples were collected during routine diagnostic, prognostic and therapy monitoring procedures in patients with colorectal and pancreatic cancer. We used ARCHITECT i2000SR and Cobas E601 for CEA analysis in sera samples.Results: The correlation coefficient of 0.984 [95% CI: 0.972 to 0.991] for results obtained on both platforms was observed for CEA≤10 ng/mL group. Moreover, intercept of 0.9027 [95% CI: 0.705 to 1.099] and slope 0.8076 [95% CI: 0.765 to 0.8498]  (p 10 ng/mL group we observed slope = 1.1986  [95%CI: 1.1474 to 1.2498]  (p 10 ng/mL were 0.2066 (95% CI: 0.0019 to 0.4113) and –2.66 (95% CI: -10.10 to 4.76) ng/mL, respectively.Conclusion: Although there were differences, based on 20 days precision tests, overall results showed a good analytical performance and correlation between CEA assays on ARCHITECT i2000SR and Cobas E601 platforms. Reference intervals appropriate for the method of CEA measurement should be used. The standardization and harmonization of serum CEA concentration assays are needed.
机译:介绍:癌胚抗原(CEA)用于监测癌症患者的疾病进展和治疗反应。我们的目的是将化学发光微粒免疫测定(CMIA)与CEA的电化学发光免疫测定(Eclia)进行比较。方法:在结直肠癌和胰腺癌患者的常规诊断,预后和治疗监测程序中收集总共115个样品。我们在血清样本中使用了建筑师I2000SR和COBAS E601进行CEA分析。结果:对于CEA≤10ng/ mL组,观察到两台平台上获得的结果0.984 [95%CI:0.972至0.991]的相关系数。此外,截止值0.9027 [95%Ci:0.705至1.099]和斜率0.8076 [95%Ci:0.765至0.8498](我们观察到斜坡= 1.1986 [95%CI:1.1474至1.2498](P 10 Ng / ml分别为0.2066(95%Ci:0.0019至0.4113),分别分别为-2.66(95%Ci:-10.10至4.76)Ng / ml。结论:虽然基于20天的精度测试,但总体结果表明了建筑师I2000SR和COBAS E601平台的CEA分析与CEA测定的良好分析性能和相关性。应使用适用于CEA测量方法的参考间隔。需要血清CEA浓度测定的标准化和协调。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号