首页> 外文OA文献 >The Use of Orientation Templates and Free-Hand Implant Insertion in Artificial Mandibles—An Experimental Laboratory Examination in Fifth-Year Dental Students
【2h】

The Use of Orientation Templates and Free-Hand Implant Insertion in Artificial Mandibles—An Experimental Laboratory Examination in Fifth-Year Dental Students

机译:使用方向模板和自由植入物插入人工颌骨 - 第五年牙科学生的实验实验室检查

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Implant dentistry is a growing field in the education of undergraduate dental students. The present laboratory study evaluates factors which may potentially influence the accuracy of free-hand implant insertion and the use of an orientation template. After three-dimensional planning using coDiagnostiXTM, orientation templates, including sleeves for the pilot-drill in regions 41 and 45, were manufactured by thermoforming. Sixty-one fifth year dental students inserted one implant using the orientation template and another implant free-hand in an artificial mandible. Information regarding age, sex, handedness, education, and the time required for implant insertion were recorded. Subsequently, the mandibles were scanned using cone-beam-computed tomography and the accuracy of the implant position was assessed, while statistical analysis followed. The free-hand implant insertion resulted in a distal deviation of −1.34 ± 5.15° and a mesial mismatch of 0.06 ± 0.79 mm at the artificial bone level compared to the sleeves. When using the orientation templates, the deviation decreased to −0.67 ± 3.48° and a distal mismatch of −0.22 ± 0.62 mm was achieved. The difference was statistically significant for the mismatch (p < 0.049). Regarding the limitations of our study, it could be said that the accuracy level achieved by dental undergraduates using implant placement with orientation templates is comparable to that in other studies.
机译:植入性牙科是本科牙科学生教育的越来越发展的领域。本实验室研究评估可能影响自由植入物插入和使用取向模板的准确性的因素。在使用CodiagnostixTM的三维规划之后,通过热成型制造了通过Codiagnostixtm的方向模板,包括用于区域41和45中的试验钻的套管。六十一年的牙科学生使用方向模板和另一个植入物在人为下颌骨中插入一个植入物。记录有关年龄,性别,手腕,教育以及植入物插入所需的时间的信息。随后,使用锥形光束计算的层析造影扫描颌骨,并评估植入位置的准确性,同时遵循统计分析。与套管相比,自由植入式插入导致远端偏差为-1.34±5.15°,在人造骨水平上的间距不匹配为0.06±0.79mm。使用方向模板时,偏差降至-0.67±3.48°,实现了-0.22±0.62mm的远侧不匹配。差异对于不匹配有统计学意义(P <0.049)。关于我们研究的局限性,可以说,牙科本科学用植入物置于方向模板实现的准确度水平与其他研究相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号